Your browser doesn't support javascript.
loading
Dosimetria de pacientes submetidos a exames de PET/CT cerebral para diagnóstico de comprometimento cognitivo leve / Dosimetry of patients submitted to cerebral PET/CT for the diagnosis of mild cognitive impairment
Santana, Priscila do Carmo; Mourão, Arnaldo Prata; Oliveira, Paulo Márcio Campos de; Bernardes, Felipe Dias; Mamede, Marcelo; Silva, Teógenes Augusto da.
  • Santana, Priscila do Carmo; Universidade Federal de Minas Gerais. Belo Horizonte. BR
  • Mourão, Arnaldo Prata; Universidade Federal de Minas Gerais. Belo Horizonte. BR
  • Oliveira, Paulo Márcio Campos de; Universidade Federal de Minas Gerais. Belo Horizonte. BR
  • Bernardes, Felipe Dias; Universidade Federal de Minas Gerais. Belo Horizonte. BR
  • Mamede, Marcelo; Universidade Federal de Minas Gerais. Belo Horizonte. BR
  • Silva, Teógenes Augusto da; Universidade Federal de Minas Gerais. Belo Horizonte. BR
Radiol. bras ; 47(6): 350-354, Nov-Dec/2014. tab, graf
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: lil-732743
RESUMO

Objetivo:

O objetivo deste trabalho é avaliar a dose em pacientes submetidos a PET/CT para diagnóstico de comprometimento cognitivo leve.

Materiais e Métodos:

Para as medidas da dose absorvida proveniente da modalidade CT utilizaram-se detectores TLD-100 inseridos em um simulador Alderson Rando®. Os simuladores antropomórficos (versões masculina e feminina) foram submetidos aos mesmos protocolos técnicos para aquisição das imagens dos pacientes. A dose absorvida resultante da injeção do radiofármaco foi estimada por meio do modelo proposto pela ICRP 106.

Resultados:

A dose efetiva a que foram submetidos os pacientes com esta técnica diagnóstica foi, aproximadamente, (5,34 ± 1,99) mSv.

Conclusão:

Protocolos otimizados para cálculo de atividade radioativa que será injetada em cada paciente podem contribuir para a redução da dose efetiva nos pacientes durante a realização do diagnóstico de comprometimento cognitivo leve com PET/CT. .
ABSTRACT

Objective:

The present study was aimed at evaluating the effective radiation dose in patients submitted to PET/CT for the diagnosis of mild cognitive impairment. Materials and

Methods:

TLD-100 detectors inserted into an Alderson Rando® anthropomorphic phantom were utilized to measure the absorbed dose coming from the CT imaging modality. The anthropomorphic phantoms (male and female adult versions) were submitted to the same technical protocols for patients’ images acquisition. The absorbed dose resulting from the radiopharmaceutical injection was estimated by means of the model proposed by the ICRP publication 106.

Results:

The effective dose in patients submitted to this diagnostic technique was approximately (5.34 ± 1.99) mSv.

Conclusion:

Optimized protocols for calculation of radioactive activity injected into patients submitted to this diagnostic technique might contribute to reduce the effective radiation dose resulting from PET/CT in the diagnosis of mild cognitive impairment. .


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica Idioma: Inglês / Português Revista: Radiol. bras Assunto da revista: Diagnóstico por Imagem / Radiologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica Idioma: Inglês / Português Revista: Radiol. bras Assunto da revista: Diagnóstico por Imagem / Radiologia Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR