Your browser doesn't support javascript.
loading
Comparação entre diferentes aparelhos de bioimpedância para avaliação do percentual de gordura / Comparison between different instruments for evaluation bioimpedance fat percentage
Reis Filho, Adilson Domingos dos; Ravagnani, Fabricio Cesar de Paula; Oliveira, Marcos Paulo Padilha de; Fett, Carlos Alexandre; Zavala, Arturo Alejandro; Coelho-Ravagnani, Christianne de Faria.
  • Reis Filho, Adilson Domingos dos; Universidade de Cuiabá. Cuiabá. BR
  • Ravagnani, Fabricio Cesar de Paula; Centro Universitário de Várzea Grande. Várzea Grande. BR
  • Oliveira, Marcos Paulo Padilha de; Universidade para o Desenvolvimento do Estado e da Região do Pantanal. Campo Grande. BR
  • Fett, Carlos Alexandre; Universidade Federal de Mato Grosso. Cuiabá. BR
  • Zavala, Arturo Alejandro; Universidade Federal de Mato Grosso. Cuiabá. BR
  • Coelho-Ravagnani, Christianne de Faria; Universidade Federal de Mato Grosso. Cuiabá. BR
Rev. bras. ciênc. mov ; 19(2): 5-12, abr.-jun. 2011. ilus
Artigo em Português | LILACS | ID: lil-733687
RESUMO
A bioimpedância (BIA) tetra polar de corpo inteiro é tida como um equipamento com melhor acurácia para a avaliação da composição corporal, porém, seu alto custo restringe sua utilização. Com isso, aparelhos de BIA com menor custo foram desenvolvidos. No entanto, a fidedignidade, confiabilidade e eficácia desses aparelhos ainda são controversas. O presente estudo objetivou comparar diferentes aparelhos de BIA para avaliação do percentual de gordura (%G) em universitários. Participaram do estudo 60 indivíduos (33 homens e 27 mulheres) com idade entre 18 e 38 anos (23,2±4,7 anos). Foram avaliados a massa corporal, a estatura e o índice de massa corporal (IMC=kg/m2). O %G foi determinado nos aparelhos de bioimpedância tetra polar de corpo inteiro Biodynamics® modelo 310 (BIO), de membros superiores OMRON® HBF 306BL (OMR) e de membros inferiores TANITA® FS088R (TAN). Utilizou-se para análise estatística o teste de Kruskal-Wallis para verificar a variância, análise de concordância através do Coeficiente de Correlação Intraclasse e plotagem de Bland-Altman. Não houve diferença estatística entre o %G obtido nos aparelhos BIO; OMR e TAN (16,4%, 14,5% e 17,3%; p=0,09) no grupo masculino e BIO; OMR e TAN (25,7%, 23,5 e 25,0%; p=0,36) para o grupo feminino. Além disso, houve correlação significativa entre os instrumentos TAN x BIO (0,76; p<0,0001), OMR x BIO (0,73; p<0,001) no grupo masculino e TAN x BIO (0,76; p<0,0001) e OMR x BIO (0,71; p<0,0001) no feminino. Foram observadas na plotagem de Bland-Altman diferenças médias próximas de zero. Não foram observadas diferenças significativas para o %G obtido pelos equipamentos de bioimpedância de corpo inteiro (Biodynamics®), de membros superiores (OMRON®) e de membros inferiores (TANITA®). Além disso, houve correlação forte e significativa entre os três aparelhos.
ABSTRACT
The bioelectrical impedance analysis (BIA) tetra polar body is taken as whole equipment with better accuracy in the assessment of body composition, but its high cost restricts their use. Yet, thetrustworthiness, reliability, and efficiency of these devices are still controversial. This study aimed atcomparing different BIA devices for the assessment of body fat percentage (%TBF) of college students. The study included 60 subjects (33 men and 27 women), ages between 18 and 38 years old (23.2±4.7 years). Weight, height, and body mass index (BMI=kg/m²) were assessed. The %TBF was determined byBiodynamics™ (BIO) full-body tetrapolar bioimpedance device, OMRON™ HBF 306 bl (OMR) upperbody bioimpedance device and TANITA™ FS088R (TAN) lower-body bioimpedance device. It was used for statistical analysis the Kruskal-Wallis test to check the variance, analysis of agreement by intraclasscorrelation and the Bland-Altman. There was no difference between the %TBF values provided by BIO, OMR and TAN devices for men (16.4%, 14.5% and 17.3%; p=0.09) and women (25.7%, 23.5 and 25%; p=0.36). Furthermore, there was a significant correlation between TAN x BIO (0.76; p<0.0001), OMR x BIO (0.73; p <0.001) devices among men, and TAN x BIO (0.76; p<0.0001) and OMR x BIO (0.71; p<0.0001) devices among women. Close to zero average differences were observed in the Bland-Altman plot. There were no significant differences between BIA devices used to determine the %TBF of these individuals. OMRON™ and TANITA™ devices are suitable for use in daily practice.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Composição Corporal / Impedância Elétrica Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. ciênc. mov Assunto da revista: Medicina Esportiva Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário de Várzea Grande/BR / Universidade Federal de Mato Grosso/BR / Universidade de Cuiabá/BR / Universidade para o Desenvolvimento do Estado e da Região do Pantanal/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Composição Corporal / Impedância Elétrica Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. ciênc. mov Assunto da revista: Medicina Esportiva Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário de Várzea Grande/BR / Universidade Federal de Mato Grosso/BR / Universidade de Cuiabá/BR / Universidade para o Desenvolvimento do Estado e da Região do Pantanal/BR