Your browser doesn't support javascript.
loading
3D computer tomography for measurement of femoral position in acl reconstruction
Fernandes, Tiago Lazzaretti; Martins, Nuno Miguel Morais Fonseca; Watai, Felipe de Andrade; Albuquerque Neto, Cyro; Pedrinelli, André; Hernandez, Arnaldo José.
  • Fernandes, Tiago Lazzaretti; University of São Paulo. Hospital das Clínicas. Institute of Orthopedics and Traumatology. BR
  • Martins, Nuno Miguel Morais Fonseca; University of São Paulo. Hospital das Clínicas. Institute of Orthopedics and Traumatology. BR
  • Watai, Felipe de Andrade; University of São Paulo. Hospital das Clínicas. Institute of Orthopedics and Traumatology. BR
  • Albuquerque Neto, Cyro; FEI University Center. Department of Mechanical Engineering. São Paulo. BR
  • Pedrinelli, André; University of São Paulo. Hospital das Clínicas. Institute of Orthopedics and Traumatology. BR
  • Hernandez, Arnaldo José; University of São Paulo. Hospital das Clínicas. Institute of Orthopedics and Traumatology. BR
Acta ortop. bras ; 23(1): 11-15, Jan-Feb/2015. fig
Artigo em Inglês | LILACS | ID: lil-735714
ABSTRACT

Objective:

To validate intra- and inter-class correlation coefficients of a transparent 3D-TC protocol and investigate relationships between different axial rotations.

Methods:

Twenty unilateral knee TCs (iSite - Philips) were evaluated by means of a transparent 3D-TC OsiriX Imaging Software (v.3.9.4), 3D MPR protocol. Mathematical model of femoral tunnel projections acquired on vertical and horizontal rotations from -20 to +20 degrees. Height (h'/H) and length (t'/T) of tunnel projections have been analyzed by the Bernard and Hertel's method. Statistics power of study=80%, ICC, ANOVA, p<0.05 (SPSS-19).

Results:

Transparent 3D-TC showed high reliability of both intra-observer (h'/H=0.941; t'/T=0.928, p<0.001) and inter-observer (h'/H=0.921; t'/T=0.890, p<0.001) ICC. ACL Length (t'/T) and Height (h'/H) projections were statistically different on vertical and horizontal rotations p=0.01 and p<0.001, respectively.

Conclusion:

This new transparent 3D-TC protocol is an accurate and reproducible method that can be applied for ACL femoral tunnel or footprint measurement with high ICC reliability. Level of Evidence II, Descriptive Laboratory Study.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Processamento de Imagem Assistida por Computador / Interpretação de Imagem Assistida por Computador / Tomografia Computadorizada por Raios X / Ligamento Cruzado Anterior / Joelho Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Acta ortop. bras Assunto da revista: Ortopedia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: FEI University Center/BR / University of São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Processamento de Imagem Assistida por Computador / Interpretação de Imagem Assistida por Computador / Tomografia Computadorizada por Raios X / Ligamento Cruzado Anterior / Joelho Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Acta ortop. bras Assunto da revista: Ortopedia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: FEI University Center/BR / University of São Paulo/BR