Your browser doesn't support javascript.
loading
Comparação entre os tempos de procedimento e fluoroscopia e o volume de contraste das vias de acesso radial e femoral em pacientes submetidos a cateterismo cardíaco / Comparison of procedural and fluoroscopy times and contrast volume between radial and femoral access for cardiac catheterization
Vargas, Túlio Torres; Campos, Barbara Cardoso; Soares, Naury de Jesus Danzi; Vitorino, Luciano Magalhães; Ibrahim, Samir Duarte; Janella, Bruno Laurenti.
  • Vargas, Túlio Torres; Faculdade de Medicina de Itajubá. Hospital Escola. Itajubá. BR
  • Campos, Barbara Cardoso; Faculdade de Medicina de Itajubá. Hospital Escola. Itajubá. BR
  • Soares, Naury de Jesus Danzi; Faculdade de Medicina de Itajubá. Hospital Escola. Itajubá. BR
  • Vitorino, Luciano Magalhães; Faculdade de Medicina de Itajubá. Hospital Escola. Itajubá. BR
  • Ibrahim, Samir Duarte; Faculdade de Medicina de Itajubá. Hospital Escola. Itajubá. BR
  • Janella, Bruno Laurenti; Faculdade de Medicina de Itajubá. Hospital Escola. Itajubá. BR
Rev. bras. cardiol. invasiva ; 22(4): 349-352, Oct-Dec/2015. tab, graf
Artigo em Português | LILACS | ID: lil-744569
RESUMO
Introdução: Há controvérsias na literatura quanto às vantagens da via radial para cateterismos diagnósticos comparadas às da via femoral. O objetivo deste estudo foi comparar o acesso pelas vias radial e femoral quanto aos tempos de procedimento e de fluoroscopia, e ao volume de contraste utilizado. Métodos: Estudo observacional, retrospectivo, realizado por meio de análise documental de registros de pacientes submetidos consecutivamente ao cateterismo cardíaco, nos meses de julho de 2012 a dezembro de 2013. Resultados: Foram analisados 192 pacientes, sendo a via radial utilizada em 78,1% dos casos. A idade dos pacientes foi de 63,1 ± 11,9 anos, a maioria era do sexo masculino (55,7%) e 21,4% eram diabéticos. O tempo do procedimento foi menor no grupo radial 12,0 minutos (9,0 a 17,2 minutos) vs. 18,3 minutos (12,0 a 34,5 minutos), p < 0,01. O tempo de fluoroscopia foi de 270,0 segundos (180,0 a 389,5 segundos) vs. 244,0 segundos (175,3 a 705,0 segundos), sem diferença entre os grupos (p = 0,59). O volume de contraste foi menor nos pacientes avaliados por via radial 100,0 mL (75,0 a 117,5 mL) vs. 100,0 mL (80,0 a 150,0 mL), p < 0,01. Conclusões: Em nosso laboratório, que privilegiou a via radial como via de acesso para cateterismos cardíacos, os tempos do procedimento e de fluoroscopia, bem como o volume de contraste, foram menores ou comparáveis aos da abordagem femoral...
ABSTRACT
Background: There is controversy in the literature about the advantages of the radial vs. femoral access route for diagnostic catheterizations. This study aimed to compare the radial and femoral access for procedural and fluoroscopy times and for contrast volume. Methods: This was an observational, retrospective study based on the records of consecutive patients undergoing cardiac catheterization from July 2012 to December 2013. Results: We evaluated 192 patients and the radial access was used in 78.1% of the cases. Mean age was 63.1 ± 11.9 years, most were male (55.7%) and 21.4% had diabetes. Procedural time was lower in the radial group: 12.0 minutes (9.0 to 17.2 minutes) vs. 18.3 minutes (12.0 to 34.5 minutes), p < 0.01. Fluoroscopy time was 270.0 seconds (180.0 to 389.5 seconds) vs. 244.0 seconds (175.3 to 705.0 seconds), and there was no difference between groups (p = 0.59). Contrast volume was lower in the radial group: 100.0 mL (75.0 to 117.5 mL) vs. 100.0 mL (80.0 to 150.0 mL), p < 0.01. Conclusions: In this laboratory, which favored the radial access for cardiac catheterization, procedural and fluoroscopy times, as well as contrast volume, were lower or comparable to the femoral access...
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fluoroscopia / Cateterismo Cardíaco / Artéria Radial / Meios de Contraste / Artéria Femoral Tipo de estudo: Estudo observacional Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. cardiol. invasiva Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Medicina de Itajubá/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fluoroscopia / Cateterismo Cardíaco / Artéria Radial / Meios de Contraste / Artéria Femoral Tipo de estudo: Estudo observacional Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. cardiol. invasiva Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2014 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Medicina de Itajubá/BR