Your browser doesn't support javascript.
loading
Alternative solution for ex vivo lung perfusion, experimental study on donated human lungs non-accepted for transplantation
Fernandes, Lucas Matos; Mariani, Alessandro Wasum; Medeiros, Israel Lopes de; Samano, Marcos Naoyuki; Abdalla, Luís Gustavo; Correia, Aristides Tadeu; Nepomuceno, Natália Aparecida; Canzian, Mauro; Pêgo-Fernandes, Paulo Manuel.
  • Fernandes, Lucas Matos; Sao Paulo University. School of Medicine. BR
  • Mariani, Alessandro Wasum; Sao Paulo University. School of Medicine. BR
  • Medeiros, Israel Lopes de; Sao Paulo University. School of Medicine. BR
  • Samano, Marcos Naoyuki; Sao Paulo University. School of Medicine. BR
  • Abdalla, Luís Gustavo; Sao Paulo University. School of Medicine. BR
  • Correia, Aristides Tadeu; Sao Paulo University. School of Medicine. BR
  • Nepomuceno, Natália Aparecida; Sao Paulo University. School of Medicine. BR
  • Canzian, Mauro; Sao Paulo University. School of Medicine. BR
  • Pêgo-Fernandes, Paulo Manuel; Sao Paulo University. School of Medicine. BR
Acta cir. bras ; 30(5): 359-365, 05/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-747026
ABSTRACT
PURPOSE: To evaluate a new perfusate solution to be used for ex vivo lung perfusion. METHODS: Randomized experimental study using lungs from rejected brain-dead donors harvested and submitted to 1 hour of ex vivo lung perfusion (EVLP) using mainstream solution or the alternative. RESULTS: From 16 lungs blocs tested, we found no difference on weight after EVLP: Steen group (SG) = 1,097±526g; Alternative Perfusion Solution (APS) = 743±248g, p=0.163. Edema formation, assessed by Wet/dry weigh ratio, was statistically higher on the Alternative Perfusion Solution group (APS = 3.63 ± 1.26; SG = 2.06 ± 0.28; p = 0.009). No difference on PaO2 after EVLP (SG = 498±37.53mmHg; APS = 521±55.43mmHg, p=0.348, nor on histological analyses: pulmonary injury score: SG = 4.38±1.51; APS = 4.50±1.77, p=0.881; apoptotic cells count after perfusion: SG = 2.4 ± 2.0 cells/mm2; APS = 4.8 ± 6.9 cells/mm2; p = 0.361). CONCLUSION: The ex vivo lung perfusion using the alternative perfusion solution showed no functional or histological differences, except for a higher edema formation, from the EVLP using Steen Solution(r) on lungs from rejected brain-dead donors. .
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Preservação de Órgãos / Perfusão / Transplante de Pulmão / Soluções para Preservação de Órgãos / Pulmão Tipo de estudo: Ensaio Clínico Controlado Limite: Adolescente / Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Acta cir. bras Assunto da revista: Cirurgia Geral / Procedimentos Cir£rgicos Operat¢rios Ano de publicação: 2015 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Sao Paulo University/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Preservação de Órgãos / Perfusão / Transplante de Pulmão / Soluções para Preservação de Órgãos / Pulmão Tipo de estudo: Ensaio Clínico Controlado Limite: Adolescente / Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Acta cir. bras Assunto da revista: Cirurgia Geral / Procedimentos Cir£rgicos Operat¢rios Ano de publicação: 2015 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Sao Paulo University/BR