Your browser doesn't support javascript.
loading
Avaliação da construção e operação de técnicas compensatórias de drenagem urbana: o transporte de finos, a capacidade de infiltração, a taxa de infiltração real do solo e a permeabilidade da manta geotêxtil / Evaluation of best management practices' construction and operation: the fine particles transportation, the infiltration capacity, the soil infiltration loading rate and the geotextile permeability
Lucas, Alessandro Hirata; Sobrinha, Loide Angelina; Moruzzi, Rodrigo Braga; Barbassa, Ademir Paceli.
  • Lucas, Alessandro Hirata; Fundação Hermínio Ometto. São Paulo. BR
  • Sobrinha, Loide Angelina; Fundação Hermínio Ometto. São Paulo. BR
  • Moruzzi, Rodrigo Braga; Fundação Hermínio Ometto. São Paulo. BR
  • Barbassa, Ademir Paceli; Fundação Hermínio Ometto. São Paulo. BR
Eng. sanit. ambient ; 20(1): 17-28, Jan-Mar/2015. tab, graf
Artigo em Português | LILACS | ID: lil-750714
RESUMO
Este trabalho avaliou aspectos da construção e operação de técnicas compensatórias em drenagem urbana e seu efeito na taxa de infiltração das unidades em escala real. Para tal, foram estudados dois sistemas, a saber i) filtro-vala-trincheira de infiltração (FVT) e ii) poço de infiltração (PI). A infiltração do solo foi avaliada por meio de ensaios de campo (ensaios de duplo anel e poço invertido) e por medidas das unidades experimentais. Além disso, foram investigados o teor de material pulverulento e a permeabilidade de amostras do geotêxtil utilizado no FVT e PI, nas condições pré e pós-instalação. A despeito das proteções instaladas, houve transporte de finos para o interior das unidades e que esses influenciaram na permeabilidade da manta geotêxtil (redução de 30 a 90% para o FVT e de 40 a 70% para o PI) e nas taxas de infiltração nas unidades em escala real (de 4,7 x 10-6 a 10-5 m.s-1). .
ABSTRACT
This work aimed to evaluate some aspects of construction and operation of full-scale best management practices and their effects on infiltration loading rate. Two systems were studied i) filter-swale-trench (FST) and ii) infiltration well (IW). In these units, field essays and full-scale measurements were made in order to assess the soil permeability. Further, the fine particles transportation and the geotextile blanket permeability were determined before and after operation. The results pointed out that there were soil transportation to inside the FST and IW systems, despite of the installed protections, and that these material were responsible for diminishing the geotextile (reduction from 30 to 90% for FST and 40 to 70% for IW) and the full-scale infiltration loading rates (varying from 4,7 x 10-6 to 10-5 m.s-1).


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo de incidência Idioma: Português Revista: Eng. sanit. ambient Assunto da revista: Saúde Ambiental / Saúde Pública Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Hermínio Ometto/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Estudo de incidência Idioma: Português Revista: Eng. sanit. ambient Assunto da revista: Saúde Ambiental / Saúde Pública Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Hermínio Ometto/BR