RESUMO
Vários estudos têm mostrado a eficiência das técnicas naturais de desaguamento do lodo das estações de tratamento de água no Brasil. O objetivo deste estudo foi avaliar o sistema de desaguamento por leito de drenagem/secagem, com manta geotêxtil dos lodos de decantadores de duas diferentes estações de tratamento de água, em ensaios de laboratório e escala reduzida. Foram considerados os parâmetros técnicos de projeto densidade da manta; taxa de aplicação dos sólidos; taxa de aplicação volumétrica e secagem em diferentes condições climáticas. Na fase de drenagem, entre 78 a 91% do volume total dos líquidos percolados apresentaram qualidade compatível com o padrão de enquadramento dos corpos de água doce classes I e II, segundo a Resolução 357/05 do Conama. Na fase de secagem, foi possível obter teores de sólidos totais entre 15,9 e 20,3%, cujos valores são da mesma ordem de grandeza que aqueles obtidos por desaguamentos mecânicos, mesmo em condições críticas de secagem.
ABSTRACT
Several studies have showed the efficiency of natural techniques to dewater the sludge from water treatment plants in Brazil. The objective of this study was to evaluate the dewatering system through drainage/drying with a geotextile blanket using the sludge of decanters from two types of water treatment plants, in laboratory experiments and reduced scale. The following technical parameters of project were considered density of blanket, application rate of solids, volumetric application rate, and drying in different climate conditions. In the drainage phase, 78 to 91% of the total volume of percolated liquid presented a compatible quality to the standardized limits for freshwater bodies from classes I and II, according to Resolution 357/05 from the National Council of Environment. In the drying phase, it was possible to obtain total solid rates between 15.9 and 20.3%, values of the same magnitude order as those obtained by mechanical drainages, even in critical drying conditions.