Your browser doesn't support javascript.
loading
Una aproximación desde la física a las consecuencias patológicas de la longitud excesiva del cordón umbilical / A physics approach to the consequences of excess umbilical cord length
Olaya-Contreras, Mercedes; Vargas-Moreno, William; Bernal-Villegas, Jaime Eduardo.
  • Olaya-Contreras, Mercedes; Pontificia Universidad Javeriana. Bogotá. CO
  • Vargas-Moreno, William; Instituto Nacional de Medicina Legal y Ciencias Forenses. Bogotá. CO
  • Bernal-Villegas, Jaime Eduardo; Pontificia Universidad Javerian. Bogotá. CO
Rev. colomb. obstet. ginecol ; 66(1): 53-60, ene.-mar. 2015. ilus
Artigo em Espanhol | LILACS | ID: lil-760899
RESUMEN

Introducción:

el cordón umbilical es una estructura incomprendida a pesar de transportar todo lo que un feto necesita para crecer y subsistir. Cada una de sus características es relevante, y la principal es la longitud, la cual, cuando está alterada, se relaciona con pobre pronóstico neurológico y muerte fetal. Materiales y

métodos:

con base en la revisión de principios físicos, se proponen fórmulas que podrían explicar la importancia de la longitud del cordón por sus repercusiones hemodinámicas.

Resultados:

se analizó la circulación fetal desde el corazón hasta la red capilar vellositaria en el plato placentario y, por medio de fórmulas físicas, se plantea la importancia de la longitud del cordón en la perfusión fetal.

Conclusiones:

las complicaciones clínicas conocidas para la excesiva longitud del cordón umbilical fueron analizadas desde el punto de vista de la física, dejando listas las fórmulas para ser alimentadas con datos reales provenientes de doppler fetales y mediciones del cordón umbilical.
ABSTRACT

Introduction:

Despite its role of transporting all the things that a foetus needs to grow and survive, the umbilical cord is still poorly understood. All of its characteristics are relevant, and paramount among them is its length. When abnormal, length is associated with poor neurological prognosis and foetal demise. Materials and

methods:

Based on a review of physics principles, formulae were proposed in an attempt to explain the importance of umbilical cord length on the basis of its haemodynamic repercussions.

Results:

Foetal circulation was analysed from the heart to the placental villous capillaries and physics formulae were used to describe the importance of umbilical cord length in foetal perfusion.

Conclusions:

Clinical complications known to be associated with excess umbilical cord length were analysed from the physics perspective, and formulae were established for use with real data derived from foetal Doppler scans and umbilical cord measurements.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Física / Trombose / Cordão Umbilical / Natimorto Tipo de estudo: Estudo prognóstico Limite: Adulto / Gravidez Idioma: Espanhol Revista: Rev. colomb. obstet. ginecol Assunto da revista: Ginecologia / Obstetrícia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Instituto Nacional de Medicina Legal y Ciencias Forenses/CO / Pontificia Universidad Javerian/CO / Pontificia Universidad Javeriana/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Física / Trombose / Cordão Umbilical / Natimorto Tipo de estudo: Estudo prognóstico Limite: Adulto / Gravidez Idioma: Espanhol Revista: Rev. colomb. obstet. ginecol Assunto da revista: Ginecologia / Obstetrícia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Instituto Nacional de Medicina Legal y Ciencias Forenses/CO / Pontificia Universidad Javerian/CO / Pontificia Universidad Javeriana/CO