Contaminação de torniquetes para punção intravenosa periférica / Contamination of tourniquets for peripheral intravenous puncture
Acta paul. enferm
;
28(5): 426-432, jul.-ago. 2015. tab
Artigo
em Português
| LILACS, BDENF
| ID: lil-766130
RESUMO
Objetivo:
Identificar a presença de contaminação em torniquetes para punção intravenosa periférica e caracterizar o perfil dos Staphylococcus spp. e leveduras isolados. Métodos Estudo transversal que inseriu análise de 18 torniquetes para punção intravenosa periférica em uso no hospital. Os torniquetes foram imersos em caldo BHI por 24h e cultivados em meios seletivos para isolamento e identificação de Staphylococcus spp. e leveduras. O método disco-difusão foi empregado para analisar o perfil de suscetibilidade dos Staphylococcus spp. aos antimicrobianos. Resultados Treze (72,2%) torniquetes apresentaram crescimento de algum micro-organismo sendo 11 (52,4%) Staphylococcus coagulase-negativo, dois (9,5%) Staphylococcusaureus, quatro (19%) Rodothorulamucilaginosa, três (14,3%) Candidaalbicans. 61,5% dos Staphylococcus spp. apresentaram resistência a oxacilina. Os profissionais da equipe não relataram protocolos para limpeza, desinfecção ou substituição controlada destes materiais na instituição. Conclusão Foi identificada a contaminação de torniquetes por micro-organismos patogênicos com perfil de resistência aos antibióticos muito utilizados em instituições hospitalares.ABSTRACT
Objectives:
To identify the presence of contamination on tourniquets for peripheral intravenous puncture and to characterize the profile of the Staphylococcus spp. and the isolated yeasts. Methods Cross-sectional study in which 18 tourniquets for peripheral intravenous puncture in use at a hospital were analyzed. The tourniquets were immersed in BHI broth for 24h and cultivated in selective media for isolation and identification of Staphylococcus spp. and yeasts. The disk-diffusion method was employed to analyze the susceptibility profile of the Staphylococcus spp. to the antimicrobial agents. Results The growth of some microorganism was identified on 13 (72.2%) tourniquets 11 (52.4%) coagulase-negative Staphylococcus, two (9.5%) Staphylococcus aureus, four (19%) Rodothorula mucilaginosa, three (14.3%) Candida albicans. 61.5% of the Staphylococcus spp. were oxacillin-resistant. The team professionals did not mention protocols for cleaning, disinfection or controlled replacement of these materials at the institution. Conclusion The contamination of tourniquets by pathogenic microorganisms was identified, with a resistance profile to the antibiotics that are frequently used in hospitals.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Infecções Estafilocócicas
/
Torniquetes
/
Contaminação de Equipamentos
/
Cuidados de Enfermagem
/
Enfermagem Prática
Tipo de estudo:
Estudo observacional
/
Estudo de prevalência
/
Fatores de risco
Limite:
Humanos
Idioma:
Português
Revista:
Acta paul. enferm
Assunto da revista:
Enfermagem
Ano de publicação:
2015
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Universidade Federal de Goiás/BR
Similares
MEDLINE
...
LILACS
LIS