Your browser doesn't support javascript.
loading
Ensaio experimental para tratamento cirúrgico das fraturas transversas da falange proximal - Técnica com parafuso intramedular cônico de compressão versus placa de compressão lateral / Experimental trial on surgical treatment for transverse fractures of the proximal phalanx: technique using intramedullary conical compression screw versus lateral compression plate
Ibanez, Daniel Schneider; Rodrigues, Fabio Lucas; Salviani, Rafael Salmeron; Roberto, Fernando Augusto Reginatto; Pengo Junior, Jose Roberto; Aita, Marcio Aurelio.
  • Ibanez, Daniel Schneider; Laboratório de Ensaios Mecânicos e Metalográficos (LEMM). Jaú. BR
  • Rodrigues, Fabio Lucas; Laboratório de Ensaios Mecânicos e Metalográficos (LEMM). Jaú. BR
  • Salviani, Rafael Salmeron; Laboratório de Ensaios Mecânicos e Metalográficos (LEMM). Jaú. BR
  • Roberto, Fernando Augusto Reginatto; Laboratório de Ensaios Mecânicos e Metalográficos (LEMM). Jaú. BR
  • Pengo Junior, Jose Roberto; Laboratório de Ensaios Mecânicos e Metalográficos (LEMM). Jaú. BR
  • Aita, Marcio Aurelio; Laboratório de Ensaios Mecânicos e Metalográficos (LEMM). Jaú. BR
Rev. bras. ortop ; 50(5): 509-514, set.-out. 2015. tab, graf
Artigo em Português | LILACS | ID: lil-766244
RESUMO
Comparar os parâmetros mecânicos entre dois métodos de estabilização por com pressão placa de compressão axial de 1,5 mm com o parafuso cônico de compressão usado como tutor intramedular.

Métodos:

Foram usados modelos de poliuretano (Sawbone(r)) que simulam a fratura da falange proximal transversa, divididos em três grupos (placa lateral, parafuso cônico, sem implante).

Resultados:

Há necessidade de uma maior força para resultar na fadiga da síntese com para fuso intramedular. Comprova-se, assim, a supremacia mecânica desse sobre o modelo com a placa lateral.

Conclusão:

A estabilização com o parafuso Acutrak(r), no tratamento das fraturas no modelo adotado neste ensaio, apresenta resultados mecânicos superiores e estatisticamente sig nificativos em comparacão com a técnica de compressão axial com o uso da placa lateral (Aptus Hand (r)).
ABSTRACT
To compare the mechanical parameters between two methods for stabilization through compression 1.5 mm axial compression plate versus conical compression screw used as an intramedullary tutor.

METHODS:

Polyurethane models (Sawbone(r)) that simulated transverse fractures of the proximal phalanx were used. The models were divided into three groups lateral plate, conical screw and no implant.

RESULTS:

Greater force was needed to result in fatigue in the synthesis using an intramedullary plate. Thus, this model was proven to be mechanically superior to the model with the lateral plate.

CONCLUSION:

Stabilization using the Acutrak(r) screw for treating fractures in the model used in this trial presents mechanical results that are statistically significantly superior to those from the axial compression technique using the lateral plate (Aptus Hand(r)).
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Traumatismos dos Dedos / Fixação de Fratura / Fixação Interna de Fraturas / Traumatismos da Mão Idioma: Português Revista: Rev. bras. ortop Assunto da revista: Ortopedia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Laboratório de Ensaios Mecânicos e Metalográficos (LEMM)/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Traumatismos dos Dedos / Fixação de Fratura / Fixação Interna de Fraturas / Traumatismos da Mão Idioma: Português Revista: Rev. bras. ortop Assunto da revista: Ortopedia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Laboratório de Ensaios Mecânicos e Metalográficos (LEMM)/BR