Your browser doesn't support javascript.
loading
Avaliação dos ruídos em uma unidade neonatal de um hospital universitário / Evaluation of noise in a neonatal unit at a university hospital
Nazário, Ariadne Pinheiro; Santos, Vivian Carolina Benetti Jacinto; Rossetto, Edilaine Giovanini; Souza, Sarah Nancy Deggau Hegeto de; Amorim, Nelma Ellen Zamberlan; Scochi, Carmen Gracinda Silvan.
  • Nazário, Ariadne Pinheiro; s.af
  • Santos, Vivian Carolina Benetti Jacinto; s.af
  • Rossetto, Edilaine Giovanini; Universidade Estadual de Londrina. Departamento de Enfermagem. BR
  • Souza, Sarah Nancy Deggau Hegeto de; Universidade Estadual de Londrina. Departamento de Enfermagem. BR
  • Amorim, Nelma Ellen Zamberlan; s.af
  • Scochi, Carmen Gracinda Silvan; Universidade de São Paulo. Escola de Enfermagem de Ribeirão Preto. Departamento de Enfermagem Materno-Infantil e Saúde Pública. BR
Semina cienc. biol. saude ; 36(1,supl): 189-198, ago. 2015. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-770852
RESUMO

Objetivo:

Identificar e mensurar as principais fontes de ruído, dimensionar os níveis de ruído no ambiente e conhecer a percepção dos funcionários acerca dos ruídos em uma Unidade Neonatal. Material e

método:

Estudo quantitativo, desenvolvido na Unidade Neonatal de um Hospital Universitário no norte do Paraná, em três etapas levantamento das principais fontes de ruído e subsequente mensuração; entrevista com a equipe multiprofissional relacionada à percepção dos mesmos acerca dos ruídos na unidade; e dimensionamento do ruído no ambiente por duas semanas não consecutivas.

Resultados:

As principais fontes ruidosas encontradas foram alarmes de monitores e equipamentos, torneira (aberta), tampa da lixeira, entre outros. A média das duas semanas foi Leq 44,4 dB, Lmax 104,5 dB, Lmin 40 dB e Lpeak de 144,8 dB. Os funcionários reconheceram que o ruído intenso acarreta prejuízo a eles e aos bebês.

Conclusão:

Constatou-se que o valor médio dos ruídos está dentro do preconizado, porém com níveis altíssimos de Lpeak e Lmax.
ABSTRACT

Objective:

To identify and measure the main sources of noise, to determine the levels of ambient noise and to know the perception of employees about noise in a Neonatal Unit. Material and

method:

A quantitative study developed in a Neonatal Unit School Hospital, Paraná, Brazil, conducted in three

steps:

identification of the main sources of noise and subsequent measure; interview with the multidisciplinary team about the perception of noise in the unit; and dimensioning noise ambient for two non-consecutive weeks.

Results:

The main sources of noise were monitor and equipment alarms, open water faucets, trash can lids, among others. The mean) of the two weeks period was Leq 44.4 dB, Lmax 104.5 dB, Lmin 40 dB and Lpeak 144.8 dB. Employees acknowledged that intense noise is prejudicial to them and to babies.

Conclusion:

It was found that the mean value of the noise is within the recommended, but with very high levels of Lpeak and Lmax.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Recém-Nascido Prematuro / Unidades de Terapia Intensiva Neonatal / Enfermagem Neonatal / Ruído Idioma: Português Revista: Semina cienc. biol. saude Assunto da revista: Biologia / Medicina Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Londrina/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Recém-Nascido Prematuro / Unidades de Terapia Intensiva Neonatal / Enfermagem Neonatal / Ruído Idioma: Português Revista: Semina cienc. biol. saude Assunto da revista: Biologia / Medicina Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Londrina/BR / Universidade de São Paulo/BR