Your browser doesn't support javascript.
loading
Validación de la escala para cribar alteración cognitiva en psiquiatría (SCIP-S) en pacientes con trastorno bipolar / Validation of the Cognitive Impairment in Psychiatry (SCIP-S) Screen Scale in Patients with Bipolar Disorder I
Castaño Ramírez, Oscar Mauricio; Martínez Ramírez, Yeferson André; Marulanda Mejía, Felipe; Díaz Cabezas, Ricardo; Valderrama Sánchez, Lenis Alexandra; Varela Cifuentes, Vilma; Aguirre Acevedo, Daniel Camilo.
  • Castaño Ramírez, Oscar Mauricio; Universidad de Caldas. Departamento de Salud Mental y Comportamiento Humano. Manizales. CO
  • Martínez Ramírez, Yeferson André; Universidad de Caldas. Departamento de Salud Mental y Comportamiento Humano. Manizales. CO
  • Marulanda Mejía, Felipe; Universidad de Caldas. Departamento de Salud Mental y Comportamiento Humano. Manizales. CO
  • Díaz Cabezas, Ricardo; Universidad de Caldas. Departamento de Salud Mental y Comportamiento Humano. Manizales. CO
  • Valderrama Sánchez, Lenis Alexandra; Universidad de Caldas. Departamento de Salud Mental y Comportamiento Humano. Manizales. CO
  • Varela Cifuentes, Vilma; Universidad de Caldas. Departamento de Salud Mental y Comportamiento Humano. Manizales. CO
  • Aguirre Acevedo, Daniel Camilo; Universidad de Caldas. Departamento de Salud Mental y Comportamiento Humano. Manizales. CO
Rev. colomb. psiquiatr ; 44(1): 20-27, ene.-mar. 2015. tab
Artigo em Espanhol | LILACS | ID: lil-770884
RESUMEN

Introducción:

La versión española de la escala para cribar alteración cognitiva en psiquiatría se ha desarrollado en respuesta a las necesidades que se presentan en la práctica clínica durante la evaluación de pacientes con enfermedad mental, pero no se conoce cómo es su comportamiento en la población colombiana con trastorno bipolar I. El presente trabajo busca establecer la validez de constructo y la estabilidad de la escala en pacientes con trastorno bipolar I de la ciudad de Manizales.

Métodos:

Se estimó la validez de constructo comparando la medición en dos grupos divergentes, grupo control y grupo con trastorno bipolar I; se comparó con una batería neuropsicológica que medía los mismos dominios de la escala; se evaluó la correlación entre cada una de las subpruebas de la escala y la estabilidad a través de la confiabilidad test-retest en el grupo con trastorno bipolar I.

Resultados:

La escala mostró capacidad discriminatoria del funcionamiento cognitivo entre el grupo control y el grupo con trastorno bipolar I. La correlación con la batería neuropsicológica se estimó por medio de la prueba de Spearman, que mostró resultados entre 0,36 y 0,77, y la correlación entre las subpruebas de la escala mostró correlaciones entre 0,39 y 0,72. La prueba test-retest se midió con el coeficiente de correlación intraclase y su valores fueron entre 0,77 y 0,91.

Conclusiones:

La versión española de la escala para criba de alteración cognitiva en psiquiatría muestra validez y confiabilidad aceptables como instrumento de medición en la practica clínica psiquiátrica.
ABSTRACT

Background:

The Spanish version of the cognitive impairment in psychiatry scale screening scale has been developed as a response to the needs arising in clinical practice during the evaluation of mental illness patients, but the performance is not known in the Colombian population with bipolar disorder I. This paper tries to establish construct validity and stability of the scale in patients with bipolar disorder I in the city of Manizales.

Methods:

Construct validity was estimated by comparing the measurement in two divergent groups, a control group and a group with bipolar disorder I. It was also compared to a Neuropsychological battery measuring the same scale domains. The correlation between each one of the sub-tests of the scale and stability was evaluated through the reliability test-retest in the group with bipolar disorder I.

Results:

The scale showed discriminatory capacity in cognitive functioning between the control group and the group with bipolar disorder I. The correlation with the neuropsycho logical battery was estimated by the Spearman test showing results between 0.36 and 0.77, and the correlation between each sub-test of the scale showed correlations between 0.39 and 0.72. Test-retest was measured with the intraclass correlation coefficient (ICC) and their values were between 0.77 and 0.91.

Conclusions:

The Spanish version of screening scale in the cognitive disorder in psychiatry shows acceptable validity and reliability as a measurement tool in clinical psychiatric practice.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Transtorno Bipolar / Transtornos Cognitivos Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Adulto / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Colômbia Idioma: Espanhol Revista: Rev. colomb. psiquiatr Assunto da revista: Psiquiatria Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad de Caldas/CO

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Transtorno Bipolar / Transtornos Cognitivos Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Adulto / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Colômbia Idioma: Espanhol Revista: Rev. colomb. psiquiatr Assunto da revista: Psiquiatria Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad de Caldas/CO