Your browser doesn't support javascript.
loading
Tratamento da má oclusão de Classe II com Distal Jet e aparelho fixo / Treatment of Class II malocclusion with the Distal Jet and fixed appliance
Higa, Rodrigo Hitoshi; Henriques, José Fernando Castanha.
  • Higa, Rodrigo Hitoshi; s.af
  • Henriques, José Fernando Castanha; Universidade de São Paulo. Faculdade de Odontologia de Bauru. Bauru. BR
Ortho Sci., Orthod. sci. pract ; 8(31): 355-362, 2015.
Artigo em Português | LILACS, BBO | ID: lil-772261
RESUMO
O presente relato de caso clínico refere-se a um tratamento de má oclusão de Classe II de Angle utilizando aparelho distalizador intrabucal Distal Jet. Este aparelho é considerado eficaz na correção dessa má oclusão e com boas alternativas para controlar os efeitos adversos oriundos do tratamento. O paciente apresentava má oclusão de Classe II divisão 1 sem componente esquelético significante. O aparelho foi eleito para este caso baseado na possível falta de colaboração do paciente e pela má oclusão encontrada. Na segunda fase do tratamento, o aparelho foi convertido em um botão de Nance para reforço de ancoragem e o aparelho fixo foi instalado com o objetivo de corrigir os efeitos colaterais resultantes da primeira fase. O aparelho extrabucal de uso noturno e elásticos de Classe II foram utilizados para evitar a mesialização dos molares durante esta fase. Ao final do tratamento foram observadas correção da relação molar, oclusão balanceada e estética.
ABSTRACT
The present case report refers to thetreatment of Angle Class II malocclusion using Distal Jet appliance. This device is considered effective in correcting this malocclusion, and has good alternatives to control the adverse effects arising from the treatment. The patient showed Class II division 1 malocclusion, without significant skeletal component. The device was cho-sen for the first phase of the treatment based on the possible lack of patient’s cooperation and the malocclusion presented. In the second phase, the Distal Jet was converted into a Nance button to reinforce the anchorage and the fixed appliance was installed to correct the side effects resulting from the first phase. The headgear for night use and Class II elastics were used to prevent mesial movement of the molars during this phase. At the end of the treatment, the molar relationship was corrected and a balanced and aesthetic occlusion was observed.
Assuntos

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Aparelhos Ortodônticos / Má Oclusão Classe II de Angle Limite: Adolescente Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Assunto da revista: Odontologia / Ortodontia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Aparelhos Ortodônticos / Má Oclusão Classe II de Angle Limite: Adolescente Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Assunto da revista: Odontologia / Ortodontia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR