Your browser doesn't support javascript.
loading
Detection of horizontal root fracture using four different protocols of cone-beam computed tomography
SALINEIRO, Fernanda Cristina Sales; PINHEIRO, Lucas Rodrigues; SANTOS JÚNIOR, Oséas dos; CAVALCANTI, Marcelo Gusmão Paraiso.
  • SALINEIRO, Fernanda Cristina Sales; Universidade de São Paulo. School of Dentistry. Department of Stomatology. São Paulo. BR
  • PINHEIRO, Lucas Rodrigues; Universidade de São Paulo. School of Dentistry. Department of Stomatology. São Paulo. BR
  • SANTOS JÚNIOR, Oséas dos; Universidade de São Paulo. School of Dentistry. Department of Stomatology. São Paulo. BR
  • CAVALCANTI, Marcelo Gusmão Paraiso; Universidade de São Paulo. School of Dentistry. Department of Stomatology. São Paulo. BR
Braz. oral res. (Online) ; 29(1): 1-6, 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-777179
ABSTRACT
The purpose of this study was to analyze four different cone-beam computed tomography (CBCT) protocols to identify horizontal root fractures (HRF) in endodontically treated teeth, with or without the presence of a metallic post. Thirty extracted single-rooted human premolars were treated endodontically. Afterwards, an observer induced a horizontal fracture in 15 teeth. Each tooth was inserted in an empty mandibular socket and submitted to a computed tomography scan taken with and without the metallic post. The acquisition followed four different protocols, with different fields of view (FOV) and voxel sizes, as follows FOV 6X16 cm/0.2 mm voxel; FOV 6X16 cm/0.25 mm voxel; FOV 8X8 cm/0.2 mm voxel; FOV 8X8 cm/0.25 mm voxel. Two observers checked all the acquisitions within a two-week interval, and the values of sensitivity, specificity, accuracy and kappa were calculated. The sensitivity, specificity and accuracy values were better for the 8X8 cm/0.2 mm and 16X6 cm/0.25 mm protocols, ranging from 0.60 to 0.86 and 0.53 to 0.80, respectively. The intra- and interobserver concordance ranged from 0.65 to 0.72. The protocols where FOV and voxel were proportional showed better results. The 8x8 cm/0.2 mm protocol had the least interference from the metallic artifact. All four protocols showed a decline in values in the presence of the metallic artifact.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fraturas dos Dentes / Raiz Dentária / Dente não Vital / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2015 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Fraturas dos Dentes / Raiz Dentária / Dente não Vital / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2015 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR