A influência de diferentes materiais de revestimento oclusal em implantes regulares / The influence of different occlusal coating materials in regular implants
Odontol. clín.-cient
; 12(3): 231-235, Jul.-Set. 2013. ilus, tab
Article
em Pt
| LILACS
| ID: lil-778255
Biblioteca responsável:
BR97.1
RESUMO
Fatores biomecânicos estão relacionados com a perda de implantes osseointegráveis, e, assim, uma análise rigorosa na seleção do melhor material oclusal para dissipação de tensões é necessária. Dessa forma, o objetivo deste estudo foi avaliar a influência de diferentes materiais oclusais no sistema coroa-implante, com destaque para o parafuso da coroa. Para isso, quatro modelos tridimensionais foram criados com um implante (Conexão Master Screw, Sistemas de Próteses, São Paulo, Brasil) do tipo hexágono externo de 3.75 mm x 10 mm com as seguintes coroas NiCr, metalo-cerâmica (porcelana), resina composta e resina acrílica. Os resultados foram visualizados através dos mapas de tensão von Mises de cada modelo proposto. Os diferentes modelos analisados apresentaram um padrão de distribuição de tensões semelhantes. Assim, concluiu-se que os diferentes materiais oclusais foram semelhantes entre si, na coroa e no parafuso. O carregamento oblíquo foi o mais prejudicial quando comparado com o carregamento axial.
ABSTRACT
Biomechanical factors are related to the loss of dental implants, and a rigorous analysis in selecting the best material for occlusal stress distribution is required. In addition, it was suggested that occlusion material can also influence the distribution of stresses. The aim of this study was to evaluate the influence of different occlusal materials on the crown-implant system, especially the screw crown. Thus, four dimensional models were created with a hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 10 mm with the following crowns NiCr, metal-ceramic (porcelain) resin and composite acrylic resin. The results were visualized through von Mises stress maps of each model. The different models analyzed showed a pattern of similar tensions distribution. Thus, it was concluded that the different occlusal materials were similar among themselves regarding the crown and screw. The oblique loading was more detrimental when compared to axial loading.
Texto completo:
1
Índice:
LILACS
Tipo de estudo:
Prognostic_studies
Idioma:
Pt
Revista:
Odontol. clín.-cient
Assunto da revista:
Odontologia
Ano de publicação:
2013
Tipo de documento:
Article