Efectos del láser de baja intensidad (As-Ga-Al 904 nm) sobre el cóndilo mandibular de conejos: análisis a través de tomografía computadorizada cone beam / Effects of low-level laser (Ga-Al-As 904 nm) on the mandibular condyle of rabbits: analysis by cone beam computed tomography
Int. j. morphol
; 34(1): 218-222, Mar. 2016. ilus
Article
em Es
| LILACS
| ID: lil-780497
Biblioteca responsável:
CL1.1
RESUMEN
En la literatura científica los efectos adversos del láser de baja intensidad (LBI) no están descritos de forma precisa, tampoco su inocuidad. El objetivo de este estudio fue evaluar el efecto de distintas dosis de LBI en el cóndilo mandibular de conejos. Dieciséis conejos divididos aleatoriamente en cuatro grupos experimentales (GE) de 4 animales fueron utilizados en este estudio. Se realizó un examen de tomografía computarizada cone beam (TCCB) de ambas articulaciones temporomandibulares (ATMs) de todos los animales que fueron utilizadas como control (GC). Luego, irradiamos cada ATM con LBI (As-Ga-Al 904 nm), 100 mW, spot 0,2 cm2, dos puntos, 3 veces/semana, totalizando 10 veces, con dosis de 15 J/cm2 (GE-1), 45 J/cm2 (GE-2), 60 J/ cm2 (GE-3) y 90 J/cm2 (GE-4). Después de 20 días de la última irradiación se realizó un nuevo examen de TCCB y luego se obtuvo las mediciones de los cóndilos en los planos coronal y sagital. Para el análisis estadístico se utilizó las pruebas de ANOVA y t-student. Los valores promedios encontrados para el GE fueron mayores que los encontrados para el GC, en los planos coronal y sagital. Hubo diferencia estadística significativa para el grupo 1 y entre los grupos 1 y 2. Concluimos que los valores promedios encontrados en las mediciones de los cóndilos mandibulares, sometidos a las dosis de LBI utilizadas en este estudio, fueron mayores que los encontrados para el GC en los planos coronal y sagital. Además, la TCCB demostró ser un método eficaz para el análisis de las dimensiones condilares.
ABSTRACT
In the scientific literature the adverse effects of Low Level Laser (LLL) are not precisely described, neither is their safety. The aim of this study was to evaluate the effect of different protocol doses of laser on the mandibular condyle of rabbits. Sixteen rabbits randomly divided into four experimental groups (EG) of 4 animals were used in this study. We carried out a cone beam computed tomography (CBCT) examination of both temporomandibular joints (TMJs) of all animals which were used as control. Subsequently, we radiated each TMJ with LLL (Ga-Al-As 904 nm), 100mW, spot 0.2 cm2, two points, 3 times/week, totaling 10 times, with doses of 15 J/cm2 (EG-1), 45 J/cm2 (EG-2), 60 J/cm2 (EG-3) and 90 J/cm2 (EG-4). After 20 days of the last irradiation we performed a new CBCT exam and then the measurement of the condyles on the coronal and sagittal planes was obtained. In the analysis of the results ANOVA and t-student for correlated samples was used. The average values found for the EG were higher than those found for CG for both the coronal and sagittal planes. There was a significant statistical difference for group 1 and between the groups 1 and 2. We concluded that the average values found in the measurements of the mandibular condyles, submitted to doses of LLL used in this study, were higher than those found for the control group in both the coronal and sagittal planes. Furthermore, the CBCT proved to be an effective method for analysis of condylar dimensions.
Palavras-chave
Texto completo:
1
Índice:
LILACS
Assunto principal:
Articulação Temporomandibular
/
Terapia com Luz de Baixa Intensidade
/
Côndilo Mandibular
Limite:
Animals
Idioma:
Es
Revista:
Int. j. morphol
Assunto da revista:
ANATOMIA
Ano de publicação:
2016
Tipo de documento:
Article
/
Project document