Your browser doesn't support javascript.
loading
Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement
Rosa, Dayana P; Borstad, John D; Pires, Elisa D; Camargo, Paula R.
  • Rosa, Dayana P; Universidade Metodista de Piracicaba. Piracicaba. BR
  • Borstad, John D; Universidade Metodista de Piracicaba. Piracicaba. BR
  • Pires, Elisa D; Universidade Metodista de Piracicaba. Piracicaba. BR
  • Camargo, Paula R; Universidade Metodista de Piracicaba. Piracicaba. BR
Braz. j. phys. ther. (Impr.) ; 20(2): 176-183, Mar.-Apr. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-783878
ABSTRACT
Background: Pectoralis minor adaptive shortening may change scapula resting position and scapular kinematics during arm elevation. A reliable and clinically feasible method for measuring pectoralis minor length will be useful for clinical decision making when evaluating and treating individuals with shoulder pain and dysfunction. Objectives: To evaluate intrarater, interrater, and between-day reliability of a pectoralis minor (PM) muscle length measurement in subjects with and without signs of shoulder impingement. Method: A convenience sample of 100 individuals (50 asymptomatic and 50 symptomatic) participated in this study. Intra- and interrater reliability of the measurement was estimated in 50 individuals (25 asymptomatic and 25 symptomatic), and between-day reliability of the measurement repeated over an interval of 7 days was estimated in an independent sample of 50 additional participants. Pectoralis minor length was measured using a flexible tape measure with subjects standing. Results: Intraclass correlation coefficients (ICC3,k) for intrarater and interrater reliability ranged from 0.86-0.97 and 0.95 for between-day reliability in both groups. Standard error of measurements (SEM) ranged from 0.30-0.42 cm, 0.70-0.84 cm, and 0.40-0.41 cm for intrarater, interrater, and between-day reliability, respectively, across the sample. The minimal detectable change (MDC) for between-day measurements ranged from 1.13-1.14 cm for both groups. Conclusions: In asymptomatic individuals and in those with signs of shoulder impingement, a single rater or pair of raters can measure pectoralis minor muscle length using a tape measure with very good reliability. This measurement can also be reliably used by the same rater over a seven day interval.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Músculos Peitorais / Exame Físico / Ombro / Amplitude de Movimento Articular / Síndrome de Colisão do Ombro / Dor de Ombro Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Braz. j. phys. ther. (Impr.) Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Metodista de Piracicaba/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Músculos Peitorais / Exame Físico / Ombro / Amplitude de Movimento Articular / Síndrome de Colisão do Ombro / Dor de Ombro Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Braz. j. phys. ther. (Impr.) Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Metodista de Piracicaba/BR