Your browser doesn't support javascript.
loading
Dermatitis por contacto a implantes metálicos / Contact dermatitis to metal implants
Luna, Amalia María; Russo, Juan Pedro; La Forgia, Marta; Infante, Lucrecia; Cannavó, Alicia; Kvitko, Elena.
  • Luna, Amalia María; Hospital General de Agudos General San Martín. Buenos Aires. AR
  • Russo, Juan Pedro; Hospital General de Agudos General San Martín. Buenos Aires. AR
  • La Forgia, Marta; Hospital General de Agudos Dr. J. M. Penna. Servicio de Dermatología. Buenos Aires. AR
  • Infante, Lucrecia; Hospital de Clínicas José de San Martín. Servicio de Dermatología. Buenos Aires. AR
  • Cannavó, Alicia; Hospital Municipal Prof. Dr. Bernardo Houssay. Buenos Aires. AR
  • Kvitko, Elena; Hospital de Clínicas José de San Martín. Sección Dermatitis por Contacto y Dermatología Ocupacional e Industrial. Buenos Aires. AR
Dermatol. argent ; 21(4): 272-276, 2015. ilus
Artigo em Espanhol | LILACS | ID: lil-784776
RESUMEN
Las reacciones cutáneas a implantes metálicos, ortopédicos u otros, están bien documentadas en la literatura. Las reacciones de hipersensibilidad al metal de los dispositivos implantados siguen siendo un tema difícil y controvertido. Los criterios y los métodos de diagnóstico no están completamente delineados aún. Hay incertidumbresy desacuerdos sobre el papel causal de la sensibilidad al metal en el funcionamiento deficiente o ante implantes fallidos. La opinión, casi de consenso, es que las pruebas del parche deben ser consideradas para los pacientes con sospecha de hipersensibilidad al metal previo al implante y en las personas con sospecha de reacciones a los mismos. Presentamos dos pacientes con sensibilidad a implantes metálicos.
ABSTRACT
Skin reactions to metal or other orthopedic implants are well documented in the literature.Hypersensitivity reactions to metal implanted devices remains a difficult andcontroversial subject. The criteria and diagnostic methods are not yet fully delineated.In addition there are uncertainties and disagreements about the causal role ofmetal sensitivity in poor performance or implant failure. The current opinion, almostconsensual, is that patch testing should be considered for patients with suspectedhypersensitivity to metal prior to implantation and those with suspected reactions tothem. We are introducing two patientsthat developed contact dermatitis secondaryto metal implants.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Próteses e Implantes / Hipersensibilidade Limite: Humanos Idioma: Espanhol Revista: Dermatol. argent Assunto da revista: Dermatologia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: Hospital General de Agudos Dr. J. M. Penna/AR / Hospital General de Agudos General San Martín/AR / Hospital Municipal Prof. Dr. Bernardo Houssay/AR / Hospital de Clínicas José de San Martín/AR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Próteses e Implantes / Hipersensibilidade Limite: Humanos Idioma: Espanhol Revista: Dermatol. argent Assunto da revista: Dermatologia Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Argentina Instituição/País de afiliação: Hospital General de Agudos Dr. J. M. Penna/AR / Hospital General de Agudos General San Martín/AR / Hospital Municipal Prof. Dr. Bernardo Houssay/AR / Hospital de Clínicas José de San Martín/AR