Your browser doesn't support javascript.
loading
Argus T® versus advance® sling for postprostatectomy urinary incontinence: a randomized clinical trial
Lima, João Paulo Cunha; Pompeo, Antonio Carlos Lima; Bezerra, Carlos Alberto.
  • Lima, João Paulo Cunha; Faculdade de Medicina ABC. Departamento de Urologia. Santo André. BR
  • Pompeo, Antonio Carlos Lima; Faculdade de Medicina ABC. Departamento de Urologia. Santo André. BR
  • Bezerra, Carlos Alberto; Faculdade de Medicina ABC. Departamento de Urologia. Santo André. BR
Int. braz. j. urol ; 42(3): 531-539, tab, graf
Artigo em Inglês | LILACS | ID: lil-785725
ABSTRACT
ABSTRACT Objective To compare the results of two slings, Argus T® and Advance®, for the treatment of postprostatectomy urinary incontinence (PPUI). Material and Methods: From December 2010 to December 2011, 22 patients with PPUI were randomized as follows: 11 (mean age 62.09(±5.30)) underwent treatment with Advance® and 11 (mean age 62.55(±8.54)) with Argus T®. All patients were evaluated preoperatively with urodynamic testing, quality of life questionnaire (ICIQ-SF), voiding diary and 24-hour pad test. Exclusion criteria were: neurological diseases, severe detrusor overactivity and urethral stenosis. Evaluation was performed at 6, 12 and 18 months after the surgery. After implantation of the Argus T® sling, patients who experienced urine leakage equal to or greater than the initial volume underwent adjustment of the sling tension. Results were statistically analyzed using the Fisher’s test, Kolmogorov-Smirnov test, Friedman’s non-parametric test or the Mann-Whitney test. Results Significant improvement of the 24-hour pad test was observed with the Argus T® sling (p=0.038) , With regard to the other parameters, there was no significant difference between the two groups. Removal of the Argus T® device due to perineal pain was performed in one patient (9%). Despite non uniform results, both devices were considered useful to improve quality of life (ICIQ-SF): Argus T® (p=0.018) and Advance® (p=0.017). Conclusions Better results were observed in the 24h pad test and in levels of satisfaction with the Argus T® device. Both slings contributed to improve quality of life (ICIQ-SF), with acceptable side effects.
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Prostatectomia / Incontinência Urinária / Slings Suburetrais Tipo de estudo: Ensaio Clínico Controlado / Estudo observacional / Estudo prognóstico Limite: Idoso / Aged80 / Humanos / Masculino Idioma: Inglês Revista: Int. braz. j. urol Assunto da revista: Urologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Medicina ABC/BR

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Prostatectomia / Incontinência Urinária / Slings Suburetrais Tipo de estudo: Ensaio Clínico Controlado / Estudo observacional / Estudo prognóstico Limite: Idoso / Aged80 / Humanos / Masculino Idioma: Inglês Revista: Int. braz. j. urol Assunto da revista: Urologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Medicina ABC/BR