Your browser doesn't support javascript.
loading
Influência de Diferentes Unidades Polimerizadoras na Resistência de União ao Cisalhamento entre Diferentes Metais e uma Resina Indireta / Effect of Different Polymerization Devices on the Shear bond Strength between Different Metals and an Indirect resin
Abreu, Celina Wanderley; Souza, Rodrigo Othávio Assunção; Passos, Sheila Pestana; Vásquez, Vanessa Zulema; Bottino, Marco Antônio.
  • Abreu, Celina Wanderley; Universidade Federal da Paraíba. Departamento de Odontologia Restauradora. João Pessoa. BR
  • Souza, Rodrigo Othávio Assunção; s.af
  • Passos, Sheila Pestana; Universidade Peruana Cayetano Heredia. Faculdade de Estomatologia. Engenharia Urb. PE
  • Vásquez, Vanessa Zulema; Universidade Estadual Paulista. Departamento de Materiais Odontológicos e Prótese. São José dos Campos. BR
  • Bottino, Marco Antônio; s.af
Rev. bras. ciênc. saúde ; 14(1): 85-92, 2010. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-790561
RESUMO
Avaliar a influência de diferentes unidadespolimerizadoras na resistência de união ao cisalhamento entrediferentes metais a uma resina laboratorial. Método: Foramconfeccionados 60 cilindros metálicos (5mm x 4mm), sendotrinta em titânio comercialmente puro (Ticp) e trinta em liga deouro-paládio (Au-Pd), jateados (Al2O3 110μm, 20s, 2,9 bar)previamente à aplicação de resina. Foram aplicadas duascamadas do opaco (Sinfony) e posteriormente foi aplicada aresina de revestimento estético Sinfony na superfície deunião ao material estético nos cilindros metálicos. O opaco ea resina de revestimento foram polimerizados em diferentesunidades, de acordo com os grupos experimentais: GrA1-Ticp + Visio Beta (3M ESPE/EUA); GrA2 – Ticp + Powerlux(EDG, Brasil); GrA3 – Ticp + Strobolux (EDG, Brasil); GrB1 –Au-Pd + Visio Beta; GrB2 – Au-Pd + Powerlux; GrB3 – Au-Pd+ Strobolux. As amostras foram submetidas ao cisalhamentoem máquina de teste universal (EMIC/Brasil) com célula decarga com capacidade de 500 Kg (0,5 mm/min). Os dadosobtidos (MPa) foram submetidos à análise de variância ANOVA2 fatores e teste Tukey (5%). Resultados: As médias edesvio-padrão obtidos foram (MPa): GrA1: 6,1±1,9; GrA2:5,6±1,4; GrA3: 5,5±2,5; GrB1:9,46±2,5; GrB2:7,4±2; GrB3:8,2±3,1. Conclusão: As ligas de Au-Pd promovem uma maiorresistência de união à resina indireta Sinfony comparado aoTicp, independente da unidade polimerizadora utilizada...
ABSTRACT
To evaluate the effect of different polymerizationunits on the shear bond strength between different metalsand a laboratorial resin. Material and Method: Sixty metalliccylinders were obtained (5mm x 4mm), thirty in commerciallypure titanium (CpTi) and thirty in gold-palladium alloy (Au-Pd),which were sandblasted (Al2O3 110μm, 20s, 2,9 bar) beforethe resin application. Two layers of opaque (Sinfony Opaque)were applied with a brush and with the assistance of theteflon matrix, the esthetic veneering resin was applied onthe metallic cylinders. The opaque and veneering resin werepolymerized at different polymerized, according toexperimental groups: GrA1 – CpTi + Visio Beta (3M ESPE/EUA); GrA2 – CpTi + Powerlux (EDG, Brazil); GrA3 – CpTi +Strobolux (EDG, Brasil); GrB1 – Au-Pd + Visio Beta; GrB2 –Au-Pd + Powerlux; GrB3 – Au-Pd + Strobolux. The specimenswere submitted to shear test in a universal testing machine(model DL/1000-EMIC) with a 500kg load cell (0,5 mm/min).The data (MPa) were submitted to the analysis of variance(ANOVA) and tukey’s test (5%). Results: The means andstandard deviations obtained were (MPa): GrA1: 6.1±1.9;GrA2: 5.6±1.4; GrA3: 5.5±2.5; GrB1: 9.4±2.5; GrB2: 7.4±2; GrB3:8.2±3.1. Conclusion: The Au-Pd alloys promote higher bondstrength to sinfony indirect resin compared to Ticp, regardlessthe polymerized unit used...
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Titânio / Resistência ao Cisalhamento / Materiais Dentários Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Português Revista: Rev. bras. ciênc. saúde Assunto da revista: Medicina Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil / Peru Instituição/País de afiliação: Universidade Estadual Paulista/BR / Universidade Federal da Paraíba/BR / Universidade Peruana Cayetano Heredia/PE

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Titânio / Resistência ao Cisalhamento / Materiais Dentários Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Português Revista: Rev. bras. ciênc. saúde Assunto da revista: Medicina Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil / Peru Instituição/País de afiliação: Universidade Estadual Paulista/BR / Universidade Federal da Paraíba/BR / Universidade Peruana Cayetano Heredia/PE