Redução cirúrgica de fratura mandibular oblíqua: Parafusos transcorticais x placas e parafusos de titânio - relatos de caso / Surgical Reduction Of Oblique Mandibular Fractures: Lag Screws X Titanium Screws And Plates - A Case Report
Pereira, Ingrid Cristina da Silva; Galdino, Amanda de Sousa; Palitó, Anna Priscila Pegado Gomes; Santos, Talita Lopes dos; Barros, Fabiana; Sobreira, Talvane.
  • Pereira, Ingrid Cristina da Silva; UNIPÊ.
  • Galdino, Amanda de Sousa; UNIPÊ.
  • Palitó, Anna Priscila Pegado Gomes; UNIPÊ.
  • Santos, Talita Lopes dos; UNIPÊ.
  • Barros, Fabiana; UNIPÊ.
  • Sobreira, Talvane; UNIPÊ.
Rev. cir. traumatol. buco-maxilo-fac ; 11(3): 69-76, Jul.-Set. 2011. ilus
Artigo em Português | LILACS | ID: lil-792211
RESUMO
O presente trabalho tem como objetivo relatar dois casos clínicos de redução de fraturas mandibulares. Caso I - Paciente do gênero masculino, branco, com 29 anos e vítima de acidente motociclístico. Ao exame clínico, evidenciaram-se edema, dor e trismo. Os exames radiográficos sugeriram fratura do lado direito da mandíbula, sendo essa transversalmente oblíqua. Considerando-se os exames clínicos e radiográficos, optou-se por uma abordagem cirúrgica para redução dos segmentos fraturados, com parafusos transcorticais. Caso II - Paciente do gênero masculino, com 35 anos e vítima de ferimento por projétil de arma de fogo. Ao exame clínico, evidenciaram-se edema e orifício de penetração do projétil. Os exames radiográficos sugeriram fratura completa da mandíbula do lado direito. Considerando-se os exames clínicos e radiográficos, optou-se por uma abordagem cirúrgica para redução dos segmentos fraturados com placa e parafusos de titânio.
ABSTRACT
The aim of the present study is to present two clinical cases of reduction of mandibular fractures. Case I: A male, white 29-year-old patient was the victim of a motorcycle accident. Physical examination revealed swelling, pain and trismus. The radiographic examinations suggested a fracture of the right side of the mandible, which is transversely oblique. On the basis of the clinical and radiographic findings a surgical approach was chosen for the reduction of the fractured segments using lag screws. Case II: A 35-year-old male patient had sustained a bullet wound from a firearm. Physical examination revealed edema and the orifice through which the projectile had passed. The radiographic examination suggested a complete fracture of the mandible on the right side. Considering the clinical and radiographic examinations, we opted for a surgical approach for the reduction of the fractured segments with titanium plates and screws.