Your browser doesn't support javascript.
loading
Resultados imediatos e de médio prazo da intervenção com stent ductal em recém-nascidos e lactentes / Immediate and medium-term outcomes of ductal stenting in neonates and infants
Vigo, Carlos Mariño; Pinedo, Gorky Mori; Mondragón, Cesar Salinas; Montes, Maria Lapoint; Manrique, Silvia Alegre; Bejarano, Geen Huaringa; Chunga, Edilberto Estela.
  • Vigo, Carlos Mariño; Instituto Nacional de Salud del Niño. Lima. PE
  • Pinedo, Gorky Mori; Hospital Nacional Dos de Mayo. Lima. PE
  • Mondragón, Cesar Salinas; Instituto Nacional de Salud del Niño. Lima. PE
  • Montes, Maria Lapoint; Instituto Nacional de Salud del Niño. Lima. PE
  • Manrique, Silvia Alegre; Instituto Nacional de Salud del Niño. Lima. PE
  • Bejarano, Geen Huaringa; Instituto Nacional de Salud del Niño. Lima. PE
  • Chunga, Edilberto Estela; Instituto Nacional de Salud del Niño. Lima. PE
Rev. bras. cardiol. invasiva ; 23(3): 211-215, jul.-set.2015. ilus
Artigo em Português | LILACS | ID: lil-794200
RESUMO
O implante de stents para manter o ducto arterial patente na cardiopatia congênita cianótica éuma alternativa à cirurgia de Blalock-Taussig modificada (BTm) em pacientes de alto risco. Descrevemos osresultados imediatos e de médio prazo do implante de stent em neonatos e lactentes com circulação pulmonarducto-dependente.

Métodos:

Trata-se de estudo descritivo e prospectivo, que incluiu diferentes cardiopatias congênitas cianóticas tratadas entre 2014 e 2015.

Resultados:

Avaliamos 14 pacientes, com média de idade de 46 dias e pesando 4,5 kg, sendo a atresia pulmonar associada à comunicação interventricular a cardiopatia mais tratada. A abordagem pela artéria femoral ocorreu em 70% dos procedimentos e, nos demais, por via carotídea. Stents de 3,5 × 12 mm foram usados na maioria dos casos, e o sucesso do implante foi obtido em 78% das intervenções (11/14). Os casos de insucesso foram encaminhados para cirurgia − uma delas em situação de urgência, que resultou em óbito. Ocorreu espasmo ductal < 48 horas em três pacientes que necessitaram de BTm, com evolução favorável. Complicações após a alta e nos primeiros 30 dias incluíram trombose de stent (2/11), uma delas controlada com redilatação e outra que evoluiu para óbito, e uma morte súbita (1/11). A mortalidade total foi de 21,4% (3/14). A patência do ducto arterial nos primeiros 6 meses foi obtida em 5 casos que foram submetidos à cirurgia paliativa.

Conclusões:

A experiência inicial de implante de stent ductal mostrou resultados imediatos favoráveis, e, emmédio prazo, mais de um terço dos pacientes com circulação pulmonar ducto-dependente manteve seus canaispatentes...
ABSTRACT
The implantation of stents to keep the ductus arteriosus patent in cyanotic congenital heart disease is an alternative to the modified Blalock-Taussig surgery (mBT) in high-risk patients. This study describes theimmediate and medium-term outcomes of stent implantation in neonates and infants with duct-dependentpulmonary circulation.

Methods:

This was a descriptive and prospective study including different cyanotic congenital heart diseases treated between 2014 and 2015.

Results:

Fourteen patients with a mean age of 46 days, and mean weight of 4.5 kg were assessed, andpulmonary artresia with interventricular communication was the most treated condition. The femoral artery approach was used in 70% of procedures; carotid approach was used in the remaining cases. Stents of 3.5 x 12 mm were used in most cases, and implant success was achieved in 78% of interventions (11/14). The failed cases were referred to surgery – one of them was an emergency, which resulted in death. Ductal spasm occurred in < 48 hours in three patients who required mBT, with favorable outcome. Complicationsafter discharge and within the first 30 days included stent thrombosis (2/11), one of which was controlled with redilation, another progressed to death, and one sudden death (1/11). The overall mortality was 21.4% (3/14). A patent ductus arteriosus in the first 6 months was present in five cases, which underwent palliative surgery.

Conclusions:

The initial experience of ductal stenting showed favorable immediate outcomes, but in the mediumterm, little more than a third of the cases maintained a patent ductus arteriosus within 6 months...
Assuntos


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Recém-Nascido / Stents / Cardiopatias Congênitas / Lactente Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Humanos / Lactente / Recém-Nascido Idioma: Português Revista: Rev. bras. cardiol. invasiva Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Peru Instituição/País de afiliação: Hospital Nacional Dos de Mayo/PE / Instituto Nacional de Salud del Niño/PE

Similares

MEDLINE

...
LILACS

LIS


Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Recém-Nascido / Stents / Cardiopatias Congênitas / Lactente Tipo de estudo: Estudo de etiologia / Estudo observacional / Fatores de risco Limite: Humanos / Lactente / Recém-Nascido Idioma: Português Revista: Rev. bras. cardiol. invasiva Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2015 Tipo de documento: Artigo País de afiliação: Peru Instituição/País de afiliação: Hospital Nacional Dos de Mayo/PE / Instituto Nacional de Salud del Niño/PE