Avaliação de dispositivos médicos nas radiografias de tórax em unidades de terapia intensiva - tempo de prestar atenção! / Evaluation of medical devices in thoracic radiograms in intensive care unit - time to pay attention!
Rev. bras. ter. intensiva
; 28(3): 330-334, jul.-set. 2016. tab, graf
Article
em Pt
| LILACS
| ID: lil-796169
Biblioteca responsável:
BR1.1
RESUMO
RESUMO Objetivo:
Identificar e avaliar o posicionamento correto dos dispositivos médicos mais comumente utilizados, observados nas radiografias de tórax de pacientes durante a permanência em unidade de terapia intensiva de nosso centro.Métodos:
Foi realizada uma pesquisa bibliográfica quanto aos critérios utilizados para avaliar o posicionamento correto dos dispositivos médicos nas radiografias de tórax. Avaliamos todas as radiografias de tórax realizadas na unidade de terapia intensiva de nosso centro durante um período de 18 meses. Incluíram-se todas as admissões nas quais foi realizada uma radiografia do tórax na unidade de terapia intensiva, nas quais fosse identificável a presença de pelo menos um dispositivo médico. Para análise, selecionou-se uma radiografia por admissão. As radiografias foram avaliadas por um observador independente.Resultados:
De um total de 2.312 radiografias analisadas, 568 foram incluídas neste estudo. Identificaram-se diversos dispositivos médicos, incluindo eletrodos de monitoramento, tubos endotraqueais, cânulas de traqueostomia, cateteres venosos centrais, marca-passos e próteses valvares cardíacas. Dentre os cateteres venosos centrais identificados, 33,6% dos subclávios e 23,8% dos jugulares estavam mal posicionados. Dentre os tubos endotraqueais, 19,9% estavam mal posicionados, enquanto todas as cânulas de traqueostomia tinham posicionamento correto.Conclusão:
Frequentemente se identificam, na radiografia de tórax realizada em pacientes na unidade de terapia intensiva, cateteres venosos e tubos endotraqueais mal posicionados. Isso é importante, pois dispositivos mal posicionados podem se relacionar a eventos adversos. Estudos futuros devem investigar possíveis associações entre o mau posicionamento dos dispositivos e eventos adversos.ABSTRACT
ABSTRACT Objective:
To identify and evaluate the correct positioning of the most commonly used medical devices as visualized in thoracic radiograms of patients in the intensive care unit of our center.Methods:
A literature search was conducted for the criteria used to evaluate the correct positioning of medical devices on thoracic radiograms. All the thoracic radiograms performed in the intensive care unit of our center over an 18-month period were analyzed. All admissions in which at least one thoracic radiogram was performed in the intensive care unit and in which at least one medical device was identifiable in the thoracic radiogram were included. One radiogram per admission was selected for analysis. The radiograms were evaluated by an independent observer.Results:
Out of the 2,312 thoracic radiograms analyzed, 568 were included in this study. Several medical devices were identified, including monitoring leads, endotracheal and tracheostomy tubes, central venous catheters, pacemakers and prosthetic cardiac valves. Of the central venous catheters that were identified, 33.6% of the subclavian and 23.8% of the jugular were malpositioned. Of the endotracheal tubes, 19.9% were malpositioned, while all the tracheostomy tubes were correctly positioned.Conclusion:
Malpositioning of central venous catheters and endotracheal tubes is frequently identified in radiograms of patients in an intensive care unit. This is relevant because malpositioned devices may be related to adverse events. In future studies, an association between malpositioning and adverse events should be investigated.Palavras-chave
Cateteres venosos centrais/utilização; Central venous catheters/utilization; Equipamentos e provisões; Equipment and supplies; Intensive care units; Intubation, intratracheal/instrumentation; Intubação intratraqueal/instrumentação; Radiografia torácica; Radiography, thoracic; Unidades de terapia intensiva
Texto completo:
1
Índice:
LILACS
Assunto principal:
Radiografia Torácica
/
Unidades de Terapia Intensiva
Tipo de estudo:
Observational_studies
/
Risk_factors_studies
Limite:
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Rev. bras. ter. intensiva
Assunto da revista:
TERAPIA INTENSIVA
Ano de publicação:
2016