Efficacy and safety of unguided percutaneous fine needle aspiration cytology in peripheral lung lesions.
J Indian Med Assoc ; 1996 Mar; 94(3): 105-7
Artigo em Inglês | IMSEAR | ID: sea-103227
ABSTRACT
The efficacy and safety of unguided percutaneous fine needle aspiration cytology in peripheral lung lesions were studied in 42 patients. The diagnostic yield of unguided aspiration was 83.3%. The yield in malignant lesion was 85.7% while in benign lesion it was 78.6%. There was no false positive report. Complications seen were asymptomatic pneumothorax and blood tinged sputum in a few cases following aspiration. The procedure was well accepted by the patients. Unguided FNAC is a simple, quick, economical, safe and reliable procedure for the diagnosis of peripheral lung lesions.
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Pneumotórax / Biópsia por Agulha / Idoso de 80 Anos ou mais / Idoso / Humanos / Criança / Reprodutibilidade dos Testes / Técnicas Citológicas / Sensibilidade e Especificidade / Adolescente Tipo de estudo: Estudo diagnóstico Limite: Aged80 Idioma: Inglês Revista: J Indian Med Assoc Ano de publicação: 1996 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Pneumotórax / Biópsia por Agulha / Idoso de 80 Anos ou mais / Idoso / Humanos / Criança / Reprodutibilidade dos Testes / Técnicas Citológicas / Sensibilidade e Especificidade / Adolescente Tipo de estudo: Estudo diagnóstico Limite: Aged80 Idioma: Inglês Revista: J Indian Med Assoc Ano de publicação: 1996 Tipo de documento: Artigo