Use of antimony (V) arsenosilicate beads for estimation of iron content of ayurvedic and allopathic preparations.
Indian J Physiol Pharmacol ; 1994 Jul; 38(3): 197-201
Artigo em Inglês | IMSEAR | ID: sea-108868
ABSTRACT
A method has been developed for the standardization of Indian ayurvedic drugs containing iron, using inorganic ion exchange material antimony (V) arsenosilicate cation exchanger. The iron present in the drug was absorbed quantitatively on the columns of the exchanger, eluted with a suitable solvent and then titrated against a standardized EDTA solution.
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Oligoelementos / Ácido Edético / Ligas / Índia / Resinas de Troca Iônica / Ferro / Ayurveda / Microesferas / Antimônio País/Região como assunto: Ásia Idioma: Inglês Revista: Indian J Physiol Pharmacol Ano de publicação: 1994 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Oligoelementos / Ácido Edético / Ligas / Índia / Resinas de Troca Iônica / Ferro / Ayurveda / Microesferas / Antimônio País/Região como assunto: Ásia Idioma: Inglês Revista: Indian J Physiol Pharmacol Ano de publicação: 1994 Tipo de documento: Artigo