Comparative study on detection of urease activity by CLO Test Kit and Microtiter Biopsy Urease Test Kit for evaluation of Helicobacter pylori
Article
| IMSEAR
| ID: sea-127041
A Microtiter Biopsy Urease Test (MBUT) for the detection of Helicobacter pylori was evaluated in the drug trial study conducted in the Endoscopy Department of New Yangon General Hospital. The MBUT was compared with commercially available urease test (CLO Test). Both CLO test and MBUT were performed on antral and fundal gastric tissues biopsied from 35 subjects who underwent upper gastrointestinal endoscopy. 29 (83 percent) cases were positive for Helicobacter pylori when tested by CLO test and MBUT. Thus the sensitivity and specificity of MBUT relative to CLO test was both 100 percent respectively. Tested by MBUT, the urease reaction was positive in 83 percent of cases within 2 hours and 90 percent within 3 hours. Tested by CLO test, it was positive in 60 percent of cases within 2 hours and 67 percent within 3 hours. the accuracy of MBUT was thus similar to that of CLO test for the detection of Helicobacter pylori. Moreover, MBUT is not expensive, can be prepared locally, packed in test kit form and can be supplied to gastroenteroscopy units for diagnostic and treatment purposes.
Texto completo:
1
Índice:
IMSEAR
Assunto principal:
Urease
/
Biópsia
/
Endoscopia Gastrointestinal
/
Helicobacter pylori
/
Mianmar
Tipo de estudo:
Diagnostic_studies
País/Região como assunto:
Asia
Ano de publicação:
1994
Tipo de documento:
Article