Your browser doesn't support javascript.
loading
Influence of different post design and composition on stress distribution in maxillary central incisor: Finite element analysis.
Artigo em Inglês | IMSEAR | ID: sea-139705
ABSTRACT

Background:

Post design and material has very important effects on dentinal stress distribution since the post placement can create stresses that lead to root fracture. Materials and

Methods:

In this study we use finite element analysis (FEA) to evaluate stress distribution on endodontically treated maxillary central incisors that have been restored with different prefabricated posts. Six models were generated from the image of anatomical plate Four metallic posts (ParaPost XH, ParaPost XT, ParaPost XP, and Flexi-Flange) and one fiberglass post (ParaPost Fiber Lux). The sixth model was a control-a sound maxillary central incisor. We used CAD software and exported the models to ANSYS 9.0. All the materials and structures were considered elastic, isotropic, homogeneous, and linear except the fiberglass post which was considered orthotropic. The values for the mechanical properties were obtained by a review of the literature and the model was meshed with 8-node tetrahedral elements. A load of 2N was applied to the lingual surface at an angle of 135°.

Results:

The stress results were recorded by shear stress and von Mises criteria; it was observed that there was no difference for stress distribution among the titanium posts in the radicular portions and into posts. There was higher stress concentration on the coronary portion with the titanium posts than with the glass fiber post. It seems that the metallic posts' external configuration does not influence the stress distribution.

Conclusion:

Fiber posts show more homogeneous stress distribution than metallic posts. The post material seems to be more relevant for the stress distribution in endodontically treated teeth than the posts' external configuration.
Assuntos

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Estresse Mecânico / Titânio / Raiz Dentária / Fenômenos Biomecânicos / Simulação por Computador / Teste de Materiais / Software / Humanos / Técnica para Retentor Intrarradicular / Planejamento de Prótese Dentária Tipo de estudo: Estudo prognóstico Idioma: Inglês Ano de publicação: 2009 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Estresse Mecânico / Titânio / Raiz Dentária / Fenômenos Biomecânicos / Simulação por Computador / Teste de Materiais / Software / Humanos / Técnica para Retentor Intrarradicular / Planejamento de Prótese Dentária Tipo de estudo: Estudo prognóstico Idioma: Inglês Ano de publicação: 2009 Tipo de documento: Artigo