Your browser doesn't support javascript.
loading
Use of optimized ultrasound axis along with marked introducer needle to prevent mechanical complications of internal jugular vein catheterization.
Ann Card Anaesth ; 2013 Oct; 16(4): 296-298
Artigo em Inglês | IMSEAR | ID: sea-149673
ABSTRACT
Internal jugular vein (IJV) catheterization is a routine technique in the intensive care unit. Ultrasound (US) guided central venous catheter (CVC) insertion is now the recommended standard. However, mechanical complications still occur due to non‑visualization of the introducer needle tip during US guidance. This may result in arterial or posterior venous wall puncture or pneumothorax. We describe a new technique of (IJV) catheterization using US, initially the depth of the IJV from the skin is measured in short‑axis and then using real time US long‑axis view guidance a marked introducer needle is advanced towards the IJV to the defined depth measured earlier in the short axis and the IJV is identified, assessed and cannulated for the CVC insertion. Our technique is simple and may reduce mechanical complications of US guided CVC insertion.
Assuntos

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Humanos / Masculino / Cateterismo Venoso Central / Adulto / Veias Jugulares Idioma: Inglês Revista: Ann Card Anaesth Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Humanos / Masculino / Cateterismo Venoso Central / Adulto / Veias Jugulares Idioma: Inglês Revista: Ann Card Anaesth Ano de publicação: 2013 Tipo de documento: Artigo