Background:
To describe the use of Ahmed glaucoma valve (AGV) in the management of intractable glaucoma in eyes with a preexisting episcleral encircling element. Materials andMethods:
This is a retrospective, consecutive, noncomparative study. The study included 12 eyes of 12 patients with a preexisting episcleral encircling element that underwent implantation of silicone AGV to treat intractable glaucoma during January 2009 to September 2010.Results:
The mean patient age was 25.6 (standard deviation 17.1) years. Five (41.6%) patients were monocular. The indications for AGV were varied. The mean duration between placement of episcleral encircling element and implantation of AGV was 30.5 (33.8) months. The mean follow-up was 37.4 (22.9) weeks. Preoperatively, the mean intraocular pressure (IOP) was 31.4 (7.9) mmHg and the mean antiglaucoma medications were 2.8. At the fi nal postoperative follow-up, the mean IOP was 12.5 (3.5) mmHg and the mean number of antiglaucoma medications was 0.8 (P < 0.001). The complications observed over the follow-up period did include corneal graft failure in three eyes, tube erosion in two eyes and rhegmatogenous retinal detachment in one eye.Conclusion:
AGV is an eff ective option in the management of intractable glaucoma in eyes with a preexisting episcleral encircling element keeping in mind the possibility of signifi cant postoperative complications.
Texto completo:
DisponíveL
Índice:
IMSEAR (Sudeste Asiático)
Idioma:
Inglês
Revista:
Indian J Ophthalmol
Ano de publicação:
2014
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS