ABSTRACT
Forty patients who were operated upon for chronic dacryocystitis six months to two years before presented with history of persistent watering and discharge. Repeat DCR with silicone tube intubation was performed in all the patients. Post-operative follow-up for a period of 12-18 months revealed absence of symptoms in 38 patients while 2 patients persisted with watering and discharge despite uncomplicated surgical procedure.