Your browser doesn't support javascript.
loading
Adequacy of hemostatic resuscitation improves therapeutic efficacy of recombinant activated factor VII and reduces reexploration rate for bleeding in postoperative cardiac surgery patients with refractory hemorrhage
Ann Card Anaesth ; 2019 Oct; 22(4): 388-393
Artigo | IMSEAR | ID: sea-185872
ABSTRACT

Background:

Excessive bleeding and surgical reexploration are common complications that increase the risk of multi-organ failure and prolonged hospitalization after cardiac surgery. Off-label use of recombinant activated factor VII (rFVIIa) is a recommended treatment for refractory bleeding.

Objective:

The objective of the study is to determine if the adequacy of hemostatic resuscitation enhances the efficacy of rFVIIa.

Methods:

This retrospective, observational, cohort study included patients who received rFVIIa for refractory postoperative bleeding after cardiac surgery. Patients were divided into two groups based on the presence or absence of adequate coagulation resuscitation before rFVIIa administration, defined as international ratio (INR) ≤1.5, platelet count ≥100 K/mL, and fibrinogen ≥200 mg/dL. The failure of rFVIIa treatment was defined as surgical reexploration within 24 h, thoracostomy drainage >400 mL/h within 6 h or transfusion of additional blood products or another rFVIIa dose within 6 h after initial rFVIIa dose.

Results:

Of the 3833 patients, screened who underwent cardiothoracic surgery procedures, 58 patients received rFVIIa for refractory postoperative bleeding. Successful hemostasis with rFVIIa was more likely in patients who were adequately resuscitated compared with those who were not (20 [71.4%] vs. 10 [33.3%], respectively; P = 0.0046). Multiple logistic regression analysis indicated that patients who were adequately resuscitated before rFVIIa were less likely to fail treatment (odds ratio, 0.16; 95% confidence interval [0.04–0.62]; P = 0.007).

Conclusions:

The therapeutic efficacy of rFVIIa is dependent on the adequacy of hemostatic resuscitation; restoration of normal serum fibrinogen, INR, and platelet counts >100 K/mL may provide an adequate substrate for rFVIIa to be effective in managing refractory postoperative cardiac surgical bleeding.

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Tipo de estudo: Estudo observacional Revista: Ann Card Anaesth Ano de publicação: 2019 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Tipo de estudo: Estudo observacional Revista: Ann Card Anaesth Ano de publicação: 2019 Tipo de documento: Artigo