Quality Improvement Initiative to Improve the Screening Rate of Retinopathy of Prematurity in Outborn Neonatal Intensive Care Graduates
Indian Pediatr ; 2018 Sep; 55(9): 780-783
Artigo | IMSEAR | ID: sea-199168
ABSTRACT

Objective:

To improve the screening rate of Retinopathy of prematurity (ROP) in theoutborn neonatal intensive care unit, using the quality improvement method.

Methods:

40 neonatal nurses, 89 parents from an outborn neonatal intensive care unit of a tertiary-carehospital were included in the study between May 2017 and March 2018. Universal samplingmethod was used.

Results:

In 345 neonates, ROP screening rate increased from 10.7%in the pre-intervention phase to 45.5% and 87.3% in the intervention and post-interventionphase, respectively.

Conclusion:

Point of care quality improvement (POCQI) methodcan be effectively used to improve ROP screening rate in outborn neonates.