Your browser doesn't support javascript.
loading
Diagnostic Accuracy of Two Softwares for Detection of Intra-Bony Lesions in Multi-Detector Computed Tomography
Artigo | IMSEAR | ID: sea-203650
ABSTRACT

Background:

Bony jaw lesions have varied radiographic appearance and may pose difficulty in establishing radiographicdifferential diagnosis. Computed tomography is a useful tool to facilitate the correct diagnosis of these bony lesions.

Objectives:

To compare the volumetric measurement of bony lesions of the jaw using two commercially available softwaresfor the evaluation of CT imaging. Material and

Methods:

All patients were subjected for multi-slice CT scanning. Thevolumetric measurements were performed using two softwares; Myrian and Siemens.

Results:

This study was conducted on15 patients of both genders; males (66.7%) and females (33.3%), where 21 diagnosed lesions with an intra-bony spaceaffecting one or both of the jaws were included in the measurements. Myrian software showed statistically lower mean ofvolumetric measurement than Somatom (P-value <0.001).

Conclusion:

Although, Myrian software showed statisticallylower mean of volumetric measurement than Somatom. The clinicalrelevance of these finding still needs to be determined infuture studies. Thus, both softwares can still be useful diagnostic tool for volumetric measurements.

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Tipo de estudo: Estudo diagnóstico Ano de publicação: 2019 Tipo de documento: Artigo