Lack of evidence for seroconversion to human immunodeficiency virus in recipients of anti-D immunoglobulin containing HIV antibody.
Artigo em Inglês | IMSEAR | ID: sea-24739
ABSTRACT
Twenty nine Rh negative women who had received injections of anti-D (Rho) immunoglobulin preparations (from an Indian firm) contaminated with antibody to human immunodeficiency virus (HIV), were tested for seroconversion to HIV, 14-38 wk after injections. All 29 were negative for HIV antibody, indicating that infectious HIV or immunogenic concentrations of inactivated HIV were not present in the investigated immunoglobulin product.
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Feminino / Humanos / Imunoglobulinas / Anticorpos Anti-HIV / Contaminação de Medicamentos / HIV / Imunoglobulina rho(D) Idioma: Inglês Ano de publicação: 1990 Tipo de documento: Artigo