Morphological & ultrastructural changes of platelet concentrates stored in PVC bags.
Artigo em Inglês | IMSEAR | ID: sea-25739
ABSTRACT
To assess the effect of storage bags on platelets, we studied the morphological and ultrastructural changes of samples drawn from platelet concentrates (PC) prepared and stored in triple, poly vinyl chloride (PVC) bags, manufactured in India. Using the scanning electron microscopy, we demonstrate formation of long pseudopods, and interaction through these to form aggregates. When platelets were stored at 23 +/- 2 degrees C, morphological changes were severe compared to the deleterious effects when kept at 22 +/- 0.5 degrees C. Ultrastructural analysis also showed that maintenance of discoid shape and prevention of granule secretion could be improved by storing the platelets at 22 +/- 0.5 degrees C. Significant degree of platelet fragmentation took place when the storage temperature was high. The morphology score done for platelets stored at both 22 +/- 0.5 degrees C and 23 +/- 2 degrees C showed that preservation of discoid shape was better with the former.
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Cloreto de Polivinila / Plaquetas / Preservação de Sangue / Humanos / Microscopia Eletrônica Idioma: Inglês Ano de publicação: 1997 Tipo de documento: Artigo