Transcatheter guidewire perforation of the pulmonary valve as a palliative procedure in pulmonary atresia with intact interventricular septum.
Indian Heart J
;
2004 Nov-Dec; 56(6): 661-3
Artigo
em Inglês
| IMSEAR
| ID: sea-2897
ABSTRACT
We report two cases of pulmonary atresia with intact interventricular septum in whom we successfully perforated and performed balloon dilation of the atretic pulmonary valve using a simple guidewire technique. The technical challenges of performing this procedure in small infants are highlighted.