Your browser doesn't support javascript.
loading
High performance liquid chromatography for determination of urinary metabolites of toluene, xylene and styrene and its application.
Southeast Asian J Trop Med Public Health ; 2008 Nov; 39(6): 1164-71
Artigo em Inglês | IMSEAR | ID: sea-35325
ABSTRACT
The purpose of this research was to determine mandelic, phenylglyoxylic, hippuric, o-, m- and p-methylhippuric acids, the six urinary metabolites of styrene, toluene and xylene by high performance liquid chromatography (HPLC). These metabolites were extracted in an acid medium, transferred into a basic solution and back extracted again using ethyl acetate, and the organic phase was evaporated to dryness under a compressed air flow at room temperature. The residue obtained was dissolved in 1 ml mobile phase solution of 0.01 M potassium orthophosphate in 0.3% acetic acid (adjusted to a pH of 2.5 with orthophosphoric acid)tetrahydrofuranacetonitrile(8758) and 100 microl was injected into a HPLC equipped with a 4.6 x 250 mm ODS3-C18 reversed phased column and ultraviolet (UV) detector at a wavelength of 254 nm. All metabolites were clearly separated within 21 minutes. The detection limits of the method were 1.1 ng/ml for PGA, 4.9 ng/ml for HA, 17.0 ng/ml for MA, 2.5 ng/ml for o-MHA, 1.7 ng/ml for p-MHA and 2.0 ng/ml for m-MHA. The percent recoveries of the six metabolites were 99.2-101.8% with percent coefficients of variation of less than 2%. The method was applied to the analysis of urine samples of twelve workers exposed to toluene, xylene and styrene in a paint factory. The 5-day post-shift urinary excretions of the six metabolites in these workers are presented. The metabolites were found at levels greater than the Biological Exposure Index (BEI) recommended by the American Conference of Governmental Industrial Hygienists (ACGIH).
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Pintura / Tolueno / Xilenos / Humanos / Calibragem / Cromatografia Líquida de Alta Pressão / Exposição Ocupacional / Sensibilidade e Especificidade / Estireno Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Southeast Asian J Trop Med Public Health Ano de publicação: 2008 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Pintura / Tolueno / Xilenos / Humanos / Calibragem / Cromatografia Líquida de Alta Pressão / Exposição Ocupacional / Sensibilidade e Especificidade / Estireno Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Southeast Asian J Trop Med Public Health Ano de publicação: 2008 Tipo de documento: Artigo