Effect of halogen light in fetal stimulation for fetal well-being assessment.
Artigo em Inglês | IMSEAR | ID: sea-43910
ABSTRACT

OBJECTIVE:

To evaluate the shortening of the time of nonstress test (NST) by using transabdominal fetal stimulation with halogen light. STUDY

DESIGN:

Experimental research. MATERIAL AND

METHOD:

The authors enrolled 176 pregnant women between 32 and 42 weeks of gestation indicated for NST at the Division of Maternal Fetal Medicine, Siriraj Hospital, Mahidol University. They were randomly assigned to receive either NST (control) or halogen light stimulation test (LST). The stimulation was performed at the beginning of the test and repeated every 10 minutes until reassuring fetal heart rate (FHR) acceleration was achieved, or up to 3 times. All tracings were interpreted blindly by one investigator at the end of the tests.

RESULTS:

The mean (+/- SD) duration from starting the test to the first FHR acceleration was not significantly different between the control group and the LST group (5.6 +/- 7.2 and 5.4 +/- 5.2 minutes, respectively). The average testing time (+/- SD) to achieved reactivity was 10.5 +/- 8.8 minutes in the controls and 9.6 +/- 6.7 minutes in the LST group. This was not statistically different. The incidence of nonreactive tests was not significantly different between the LST and the controls (15.9% and 11.4%, respectively). Among the LST subjects, term fetuses and women with BMI < 27 kg/m2 required less time to reach reactivity, 2.4 and 2.3 minutes respectively.

CONCLUSION:

Transabdominal halogen light stimulation did not shorten the duration of NST in the presented population. However, the presented data suggests that the fetus at term could respond to visual stimulation, especially when the gestational age is more advanced.
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Estimulação Luminosa / Diagnóstico Pré-Natal / Frequência Cardíaca Fetal / Feminino / Humanos / Gravidez / Nível de Saúde / Idade Gestacional / Sofrimento Fetal / Feto Tipo de estudo: Ensaio Clínico Controlado / Estudo diagnóstico Idioma: Inglês Ano de publicação: 2006 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Estimulação Luminosa / Diagnóstico Pré-Natal / Frequência Cardíaca Fetal / Feminino / Humanos / Gravidez / Nível de Saúde / Idade Gestacional / Sofrimento Fetal / Feto Tipo de estudo: Ensaio Clínico Controlado / Estudo diagnóstico Idioma: Inglês Ano de publicação: 2006 Tipo de documento: Artigo