Reduction of pacemaker-induced pectoral muscle stimulation using an insulating patch.
Indian Heart J ; 2002 Mar-Apr; 54(2): 206-7
Artigo em Inglês | IMSEAR | ID: sea-4555
ABSTRACT
An 82-year-old female patient was admitted for replacement of her pulse generator battery which had reached an end-of-life situation. The old unipolar leads were retained. Pectoral muscle stimulation began shortly after implantation. Though complete abolition of muscle stimulation was not achieved, an insulating patch placed between the muscle and the pacemaker can reduced stimulation.
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Marca-Passo Artificial / Músculos Peitorais / Idoso de 80 Anos ou mais / Idoso / Feminino / Humanos / Estimulação Cardíaca Artificial / Remoção de Dispositivo / Desenho de Equipamento / Átrios do Coração Limite: Aged80 Idioma: Inglês Revista: Indian heart j Ano de publicação: 2002 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Marca-Passo Artificial / Músculos Peitorais / Idoso de 80 Anos ou mais / Idoso / Feminino / Humanos / Estimulação Cardíaca Artificial / Remoção de Dispositivo / Desenho de Equipamento / Átrios do Coração Limite: Aged80 Idioma: Inglês Revista: Indian heart j Ano de publicação: 2002 Tipo de documento: Artigo