Your browser doesn't support javascript.
loading
Acute hemodynamic effects of different atrioventricular intervals in dual chamber pacemakers: is there an optimum atrioventricular delay.
Indian Heart J ; 1992 Mar-Apr; 44(2): 79-85
Artigo em Inglês | IMSEAR | ID: sea-5223
ABSTRACT
Conflicting data have been reported regarding adjustment of atrioventricular (AV) interval to maximise hemodynamic performance of dual chamber pacemakers. Eleven consecutive patients with complete heart block and dual chamber pacemakers were paced at three AV intervals (150, 200, 250 msec) and free running rates (60-93 bpm, mean 73 +/- 12 bpm) with simultaneous measurements of cardiac output, atrial contribution to left ventricular filling, left ventricular ejection fraction, and peak aortic velocity and acceleration by echo-Doppler techniques to define the optimum AV delay. At all the three AV intervals tested there was no difference in cardiac output (4.7 +/- 0.96, 4.83 +/- 1.12, 4.77 +/- 1.19 litres/min respectively, p = NS), left ventricular ejection fraction (60.2 +/- 10.6%, 61.2 +/- 9.9% and 64 +/- 8.3%, p = NS), atrial contribution to left ventricular filling (0.37 +/- 0.10, 0.38 +/- 0.09, 0.36 +/- 0.16, n = 8, p = NS), peak aortic velocity (104 +/- 8, 105 +/- 12, 104 +/- 13 cm/sec, p = NS) and aortic acceleration (19.68 +/- 4.26, 20.4 +/- 5.58 and 19.0 +/- 4.54 m/sec2, p = NS). Compared to AV delay of 150 msec an increase in cardiac output of 0.5 L/minute was observed in three patients at an AV delay of 200 msec and in one patient at the AV delay of 250 msec. These data suggest that it is difficult to generalize an optimum AV delay in patients with dual chamber pacemakers. With the AV interval in the range of 150-250 msec, only a minority of patients could improve their haemodynamics at rest by adjusting this interval if the baseline cardiac function was normal.
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Marca-Passo Artificial / Idoso / Feminino / Humanos / Masculino / Ecocardiografia / Função Ventricular Esquerda / Adulto / Bloqueio Cardíaco / Hemodinâmica Idioma: Inglês Revista: Indian heart j Ano de publicação: 1992 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Marca-Passo Artificial / Idoso / Feminino / Humanos / Masculino / Ecocardiografia / Função Ventricular Esquerda / Adulto / Bloqueio Cardíaco / Hemodinâmica Idioma: Inglês Revista: Indian heart j Ano de publicação: 1992 Tipo de documento: Artigo