ABSTRACT
To investigate the incidence of complications reportedly caused by the use of 5-fluorouracil (5-FU) in glaucoma filtering surgery, we performed trabeculectomy with 5-FU on 57 eyes of 56 patients with advanced glaucoma. The mean preoperative intraocular pressure was 34.8 mm Hg. The most frequent complication encountered was superficial punctate keratopathy (26%), followed by shallowing of the anterior chamber (12%), choroidal detachment (9%), and flap retraction (7%). We, however, did not encounter any cases of confluent corneal epithelial defect, subepithelial scarring, or striate melanokeratosis which are usually described with the use of 5-FU. With a mean follow-up of 7.1 months, an intraocular pressure less than 16 mm Hg without hypotensive therapy were achieved in 73.7% of cases, and less than 21 mm Hg without hypotensive therapy in 86%. Considering the low incidence of complications and the high success rate, we recommend the use of 5-FU in routine glaucoma filtering surgery.