Normal parameters of ventricular system in healthy infants.
Indian Pediatr
;
1995 May; 32(5): 549-55
Artigo
em Inglês
| IMSEAR
| ID: sea-7315
ABSTRACT
Six hundred healthy inborn newborns and infants upto the age of 18 months were studied. Cranial sonography was performed by real time 2D scanner with 5 MHz transducer and images were obtained through anterior fontanelle and temporo-squamal suture. Various parameters related to ventricular system were measured for different ages till the fontanelle remained open. These values will prove useful for diagnosing hydrocephalus at an early stage of the disease and also to find out the blocks at various levels in ventricular system.
Texto completo:
DisponíveL
Índice:
IMSEAR (Sudeste Asiático)
Assunto principal:
Valores de Referência
/
Feminino
/
Humanos
/
Masculino
/
Recém-Nascido
/
Ventrículos Cerebrais
/
Cefalometria
/
Estudos Prospectivos
/
Fatores Etários
/
Hidrocefalia
Tipo de estudo:
Estudo observacional
Idioma:
Inglês
Revista:
Indian Pediatr
Ano de publicação:
1995
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS