Oral versus axillary temperatures in human volunteers.
Artigo em Inglês | IMSEAR | ID: sea-93649
ABSTRACT
We measured the oral and axillary temperatures of 100 individuals (including 40 females) in the medical wards. Twenty six had fever ranging from 37.3 degrees C to 40.5 degrees C while the rest had normal temperature. Although the oral temperature was higher than axillary temperature in all the cases, there was no correlation between the two; in one case the difference was as high as 1 degrees C. We conclude that while recording temperature the site must be clearly stated, and no attempt must be made to extrapolate the axillary to the oral temperature.
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Axila / Temperatura Corporal / Idoso / Feminino / Humanos / Masculino / Adolescente / Adulto / Febre / Métodos Idioma: Inglês Ano de publicação: 1990 Tipo de documento: Artigo