Cardiovascular responses to cold pressor test: a test for autonomic functions.
J Indian Med Assoc ; 1991 Aug; 89(8): 229-31
Artigo em Inglês | IMSEAR | ID: sea-99232
ABSTRACT
Circulatory dynamics during the cold pressor test, done by immersing the hand in water at 5 degrees C for one minute, were studied in 30 male healthy volunteers. All the subjects responded to the test with statistically significant increase in blood pressure (22.04%, p less than 0.001), heart rate (11.21%, p less than 0.001), galvanic skin resistance (36.17%, p less than 0.001) and decrease in forearm blood flow (40.85%, P less than 0.001). The measurement of cardiovascular responses following cold pressor test constitutes another test which can be used to test the efficiency of the autonomic nervous system in various autonomic neuropathies.
Assuntos
Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Fluxo Sanguíneo Regional / Sistema Nervoso Autônomo / Pressão Sanguínea / Humanos / Masculino / Fenômenos Fisiológicos Cardiovasculares / Adolescente / Temperatura Baixa / Adulto / Antebraço Idioma: Inglês Revista: J Indian Med Assoc Ano de publicação: 1991 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: IMSEAR (Sudeste Asiático) Assunto principal: Fluxo Sanguíneo Regional / Sistema Nervoso Autônomo / Pressão Sanguínea / Humanos / Masculino / Fenômenos Fisiológicos Cardiovasculares / Adolescente / Temperatura Baixa / Adulto / Antebraço Idioma: Inglês Revista: J Indian Med Assoc Ano de publicação: 1991 Tipo de documento: Artigo