Your browser doesn't support javascript.
loading
Compliance with Positive Airway Pressure Treatment for Obstructive Sleep Apnea
Clinical and Experimental Otorhinolaryngology ; : 90-96, 2009.
Artigo em Inglês | WPRIM | ID: wpr-100528
ABSTRACT

OBJECTIVES:

Positive airway pressure (PAP) is considered a standard treatment for moderate-to-severe obstructive sleep apnea (OSA) patients. However, compliance with PAP treatment is suboptimal because of several types of discomfort experienced by patients. This study investigated compliance with PAP therapy, and affecting factors for such compliance, in OSA patients.

METHODS:

We performed a survey on 69 patients who engaged in PAP therapy between December 2006 and November 2007. After diagnostic polysomnography and manual titration, patients trialed PAP using the ResMed instrument and explored autoadjusting PAP (APAP), continuous PAP (CPAP), and flexible PAP (using expiratory pressure relief [EPR]) at least once every week for 1 month. Compliance measures were mean daily use (hr), percentage of days on which PAP was used, and percentage of days on which PAP was used for >4 hr. Data were obtained at night using the software Autoscan version 5.7(R) of the ResMed Inc. We obtained data on anthropometric (age, BMI, neck circumflex, Epworth sleepiness scale, Pittsburgh Sleep Quality Index, hypertension, alcohol intake), polysomnographic data (severity of apnea-hypopnea index [AHI], proportion of nonsupine sleep time, position dependence of sleep), PAP mode and AHI during PAP use for affecting factors.

RESULTS:

After 1 month, 41 of the 69 patients (59.4%) were pleased with PAP therapy and purchased instruments. Twenty-four patients (34.7%) used PAP for more than 3 months. The percentage of days on which PAP was used was statistically higher in patients with hypertension than in normotensive patients (P=0.003). There were negative correlations 1) between nonsupine position sleep time and percentage of days on which PAP was used (r=-0.424, P=0.039), and 2) between the AHI during PAP use and the percentage of days on which PAP was used for >4 hr (r=-0.443, P=0.030). There were no statistical differences between AHI, BMI, PAP pressure, or other measured parameters, on the one hand, and compliance, on the other.

CONCLUSION:

The affecting factors for PAP use were hypertension history, sleep posture (shorter nonsupine sleep time), and lower AHI during PAP use.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Postura / Polissonografia / Complacência (Medida de Distensibilidade) / Apneia Obstrutiva do Sono / Pressão Positiva Contínua nas Vias Aéreas / Mãos / Hipertensão / Pescoço Tipo de estudo: Guia de Prática Clínica Limite: Humanos Idioma: Inglês Revista: Clinical and Experimental Otorhinolaryngology Ano de publicação: 2009 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Postura / Polissonografia / Complacência (Medida de Distensibilidade) / Apneia Obstrutiva do Sono / Pressão Positiva Contínua nas Vias Aéreas / Mãos / Hipertensão / Pescoço Tipo de estudo: Guia de Prática Clínica Limite: Humanos Idioma: Inglês Revista: Clinical and Experimental Otorhinolaryngology Ano de publicação: 2009 Tipo de documento: Artigo