Your browser doesn't support javascript.
loading
Accidental discovery of copy number variation on chromosome 1 in a fetus with high risk of trisomy 13 suggested by NIPT / 中华医学遗传学杂志
Chinese Journal of Medical Genetics ; (6): 922-927, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1009235
ABSTRACT
OBJECTIVE@#To validate a fetus with high risk for trisomy 13 suggested by non-invasive prenatal testing (NIPT).@*METHODS@#The fetus was selected as the study subject after the NIPT detection at Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences on February 18, 2019. Clinical data of the pregnant woman was collected. Fluorescence in situ hybridization (FISH), chromosomal karyotyping analysis and chromosomal microarray analysis (CMA) were carried out on amniotic fluid and umbilical cord blood and the couple's peripheral blood samples. Copy number variation sequencing (CNV-seq) was also performed on the placental and amniotic fluid samples following induced labor.@*RESULTS@#The pregnant woman, a 38-year-old G4P1 gravida, was found to have abnormal fetal development by prenatal ultrasonography. NIPT test suggested that the fetus has a high risk for trisomy 13. Chromosomal karyotyping analysis of fetal amniotic fluid and umbilical cord blood were 46,XN,add(13)(p10). The result of CMA was arr[hg19]1q41q44(223937972_249224684)×3, with the size of the repeat fragment being approximately 25.29 Mb, the fetal karyotype was thereby revised as 46,XN,der(13)t(1;13)(q41;p10). Chromosomal karyotyping analysis and CMA of the parents' peripheral blood samples showed no obvious abnormality. The CNV-seq analysis of induced placenta revealed mosaicisms of normal karyotype and trisomy 13. The CNV-seq test of induced amniotic fluid confirmed a duplication of chr122446001_249220000 region spanning approximately 24.75 Mb, which was in keeping with the CMA results of amniotic fluid and umbilical cord blood samples.@*CONCLUSION@#NIPT may yield false positive result due to placenta mosaicism. Invasive prenatal diagnosis should be recommended to women with a high risk by NIPT test. And analysis of placenta can explain the inconsistency between the results of NIPT and invasive prenatal diagnosis.
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Placenta / Diagnóstico Pré-Natal / Trissomia / Cromossomos Humanos Par 1 / Aberrações Cromossômicas / Hibridização in Situ Fluorescente / Variações do Número de Cópias de DNA / Feto / Síndrome da Trissomia do Cromossomo 13 / Líquido Amniótico Limite: Feminino / Humanos / Gravidez Idioma: Chinês Revista: Chinese Journal of Medical Genetics Ano de publicação: 2023 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Placenta / Diagnóstico Pré-Natal / Trissomia / Cromossomos Humanos Par 1 / Aberrações Cromossômicas / Hibridização in Situ Fluorescente / Variações do Número de Cópias de DNA / Feto / Síndrome da Trissomia do Cromossomo 13 / Líquido Amniótico Limite: Feminino / Humanos / Gravidez Idioma: Chinês Revista: Chinese Journal of Medical Genetics Ano de publicação: 2023 Tipo de documento: Artigo