Your browser doesn't support javascript.
loading
Results of Revision Surgery and Causes of Unstable Total Knee Arthroplasty
Clinics in Orthopedic Surgery ; : 165-172, 2014.
Artigo em Inglês | WPRIM | ID: wpr-100972
ABSTRACT

BACKGROUND:

The aim of this study was to evaluate causes of unstable total knee arthroplasty and results of revision surgery.

METHODS:

We retrospectively reviewed 24 knees that underwent a revision arthroplasty for unstable total knee arthroplasty. The average follow-up period was 33.8 months. We classified the instability and analyzed the treatment results according to its cause. Stress radiographs, postoperative component position, and joint level were measured. Clinical outcomes were assessed using the Hospital for Special Surgery (HSS) score and range of motion.

RESULTS:

Causes of instability included coronal instability with posteromedial polyethylene wear and lateral laxity in 13 knees, coronal instability with posteromedial polyethylene wear in 6 knees and coronal and sagittal instability in 3 knees including post breakage in 1 knee, global instability in 1 knee and flexion instability in 1 knee. Mean preoperative/postoperative varus and valgus angles were 5.8degrees/3.2degrees (p = 0.713) and 22.5degrees/5.6degrees (p = 0.032). Mean postoperative alpha, beta, gamma, delta angle were 5.34degrees, 89.65degrees, 2.74degrees, 6.77degrees. Mean changes of joint levels were from 14.1 mm to 13.6 mm from fibular head (p = 0.82). The mean HSS score improved from 53.4 to 89.2 (p = 0.04). The average range of motion was changed from 123degrees to 122degrees (p = 0.82).

CONCLUSIONS:

Revision total knee arthroplasty with or without a more constrained prosthesis will be a definite solution for an unstable total knee arthroplasty. The solution according to cause is very important and seems to be helpful to avoid unnecessary over-constrained implant selection in revision surgery for total knee instability.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Reoperação / Falha de Prótese / Estudos Retrospectivos / Artroplastia do Joelho / Instabilidade Articular / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Estudo de etiologia / Estudo observacional Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Clinics in Orthopedic Surgery Ano de publicação: 2014 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Reoperação / Falha de Prótese / Estudos Retrospectivos / Artroplastia do Joelho / Instabilidade Articular / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Estudo de etiologia / Estudo observacional Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Clinics in Orthopedic Surgery Ano de publicação: 2014 Tipo de documento: Artigo