Discussion on results of national measurement capability comparison assessment for gross α and gross β radioactivity in water and calculation formulas for spike recovery / 中国辐射卫生
Chinese Journal of Radiological Health ; (6): 46-50, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1012769
ABSTRACT
Objective To summarize and analyze the difficulties and key points in the measurement of gross α and gross β radioactivity in water based on the results of national measurement capability comparison assessment, and provide the basis and reference for the future work and the development of new local standards. Methods The research team participated in the comparison assessment for measurement of the gross radioactivity in water samples organized by National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention. According to the comparison assessment results and the content in the national standard GB/T 5750.13—2023 (published draft), the steps of spike recovery involved during the measurement were analyzed and discussed. Two different formulas used for spike recovery calculation were analyzed for their impact on the final measurement results. Results When the spike recovery F(derived) derived from the formulas was used for result calculation, the spike recovery ranged as follows gross α 63.00%−84.60%, and gross β 95.0%−99.1%; 3/6 of the comparison results were determined as excellent and 3/6 as pass as a whole (among them, 4 were excellent and 2 were pass for both single gross α assessment items and single gross β assessment items). When the spike recovery F from the GB/T 5750.13—2023 (published draft) was used for result calculation, the spike recovery ranged as follows gross α 39.69%−71.57%, and gross β 90.25%−98.21%; 5/6 of the comparison results were determined as fail and 1/6 as pass (among them, 5 were fail and 1 was pass for single gross α assessment items; 5 were excellent and 1 was pass for single gross β assessment items). When two different formulas were used for spike recovery calculation, there was a significant difference in gross α radioactivity measurement (t = 4.27, P = 0.03 < 0.05), but there was no significant difference in gross β radioactivity measurement (t = 0.667, P = 0.524 > 0.05). Conclusion In the measurement of gross α and gross β radioactivity in water, appropriate reference to the spike recovery has a great influence on the measurement results. Therefore, quality control should be strengthened to further ensure the accuracy of measurement.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Health Ano de publicação: 2024 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Health Ano de publicação: 2024 Tipo de documento: Artigo