Your browser doesn't support javascript.
loading
Radiologic Measurement of Tibial Tuberosity-Trochlear Groove (TT-TG) Distance by Lower Extremity Rotational Profile Computed Tomography in Koreans
Clinics in Orthopedic Surgery ; : 45-48, 2016.
Artigo em Inglês | WPRIM | ID: wpr-101616
ABSTRACT

BACKGROUND:

Tibial tuberosity-trochlear groove (TT-TG) distance is important in the assessment and treatment of patellofemoral disorders. However, normal and pathological TT-TG values have not been established in Koreans. The purpose of this study was to evaluate the TT-TG distance in the Korean population using lower leg rotational profile computed tomography (CT) scans.

METHODS:

One hundred rotational profile CT scans were retrospectively collected from patients without knee joint problems aged between 25 to 82 years. TT-TG distances were measured, and statistical analysis was performed. Each CT scan was measured twice in a blinded, randomized manner by three reviewers. Patients with pre-existing knee joint problems were excluded from the study; hence 15 of the 100 patients were excluded because of deformity or unreadable CT scans. Thus, 85 of the 100 patients were included in the study.

RESULTS:

Interobserver and intraobserver reliability of TT-TG distance measurements was good. The median TT-TG distance for this Korean population was 11.24 mm (mean, 10.24 +/- 0.8 mm). TT-TG distance measured nearly 2 mm less on rotational profile CT scans.

CONCLUSIONS:

Some of the TT-TG distances on rotational profile CT scans were significantly correlated, indicating that they could be accepted. Furthermore, the values on CT scans showed good reliability. In this study, the TT-TG distance in normal Korean people was approximately 10.24 mm without significant differences in TT-TG values between genders.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Valores de Referência / Tíbia / Tomografia Computadorizada por Raios X / Fêmur / República da Coreia / Perna (Membro) Tipo de estudo: Ensaio Clínico Controlado Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino País/Região como assunto: Ásia Idioma: Inglês Revista: Clinics in Orthopedic Surgery Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Valores de Referência / Tíbia / Tomografia Computadorizada por Raios X / Fêmur / República da Coreia / Perna (Membro) Tipo de estudo: Ensaio Clínico Controlado Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino País/Região como assunto: Ásia Idioma: Inglês Revista: Clinics in Orthopedic Surgery Ano de publicação: 2016 Tipo de documento: Artigo