Your browser doesn't support javascript.
loading
Quality control of the total blood, erythroprecipitin and condensed thrombocyte according to the ISO 9002 in the Ho Chi Minh Center for hematology and blood transfusion
Journal of Vietnamese Medicine ; : 21-23, 2001.
Artigo em Vietnamita | WPRIM | ID: wpr-1032
ABSTRACT
203 products of total blood and 203 products of the erythroprecipitin undergone the quality control during 1/200-27/9/2000. The results have shown that the blood volume of 4.92% products was lower than 250 ml and level of hemoglobin of 1% products was lower than 22g among 203 controlled products of the total blood; volume of 2.11% products was less than 125ml and of 12.67% products was more than 125 ml; the level of hemoglobin of 100% products was higher than 22 g and of 80% products was higher than 25g, the hematocrite of 4.22% products was higher than 0.75 l/l among 142 controlled products of the erythroprecipitin. The

conclusion:

products, in generally obtained the ISO 9002.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Controle de Qualidade / Sangue / Plaquetas / Eritrócitos Idioma: Vietnamita Revista: Journal of Vietnamese Medicine Ano de publicação: 2001 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Controle de Qualidade / Sangue / Plaquetas / Eritrócitos Idioma: Vietnamita Revista: Journal of Vietnamese Medicine Ano de publicação: 2001 Tipo de documento: Artigo